Kingfisher Plus+ Hardware Manual
DIGITAL OUTPUTS
Outputs per Module
8
Comm ons
1 (common supplies all 8 outputs)
Rela y T ype
SPST (Single Pole Single Throw)
Maxim um Switched
Voltage
30 V
DC
, 42 V
AC
Maxim um Switched
Current
5 A per common
Isolation
3 kV coil to contacts
Minim um Load
10 mA @ 5 V
DC
Contact Resistance
100 m
Ω
maximum
Rela y Operations
70,000 minimum at 1800 operations per hour at rated load
Rela y Part Num ber
Omron G6D-1A 12 V
DC
(G6D datasheet is available from
CAUTION!
Contacts should be protected with appropriate suppression devices when wired with
inductive loads to increase the service life of relays (please see the
section for more details). Contacts should also be protected with external fusing.
14.1.4 IO-2 Wiring Diagram
The insert in the hinged cover of the terminal strip has circuit wiring information. Circuit
identification information can be recorded on the outside surface of the insert.
Hardware Manual Version 7.16
http://www.servelec-semaphore.com/
Page 200