POTENTIAL CONSEQUENCE

Serious injury or death could occur if
the air compressor is not properly
grounded. Your air compressor is
powered by electricity and may cause
electric shock or electrocution if not
used properly.

Electrical shock may occur from
electrical cord.

Electrical shock may occur if air
compressor is not operated properly.

Serious injury or death may occur if
electrical repairs are attempted by
unqualified persons.

PREVENTION

Make sure the air compressor is
plugged into a properly grounded
outlet which provides correct
voltage and adequate fuse
protection.

Check power cord for signs of
crushing, cutting or heat damage.
Replace faulty cord before use.

Keep all connections dry and off the
ground. Do not allow electrical
cords to lay in water or in such a
position where water could come in
contact with them. Do not touch
plug with wet hands.

Do not pull on the electrical cord to
disconnect from the outlet.

Never operate air compressor in
wet conditions or outdoors when it
is raining.

Never operate air compressor with
safety guards/covers removed or
damaged.

Any electrical wiring or repairs
performed on this air compressor
should be done by Authorized
Service Personnel in accordance
with National and Local electrical
codes.

Before opening any electrical
enclosure, always shut off the air
compressor, relieve pressure and
unplug the air compressor from the
power source. Allow air compressor
to cool down. Never assume the air
compressor is safe to work on just
because it is not operating. It could
restart at any time!

HAZARD

RISK OF

ELECTRIC SHOCK

OR

ELECTROCUTION

SAFETY WARNINGS

READ ALL SAFETY WARNINGS BEFORE USING AIR COMPRESSOR

Summary of Contents for PC 2001

Page 1: ...r the safe use of this compressor are included in this manual PC 1001 Electric Air Compressor Document FN1001 Issued 5 30 A Questions Comments call SENCO S toll free Action line 1 888 222 8144 or e ma...

Page 2: ...5 BREATHING 6 BURNS 6 FLYING OBJECTS 6 MOVING PARTS 7 NEGLIGENCE 7 AIR COMPRESSOR DAMAGE 7 COMPRESSOR FEATURES 8 PREPARATION 10 INITIAL SET UP 10 LOCATION 10 ELECTRICAL 10 OPERATION 11 PRE START CHECK...

Page 3: ...ot avoided WILL result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury CAUTION Indicates a potentially hazar...

Page 4: ...electrical cords to lay in water or in such a position where water could come in contact with them Do not touch plug with wet hands Do not pull on the electrical cord to disconnect from the outlet Nev...

Page 5: ...ble dust gases or other combustible materials If spraying flammable material locate the air compressor at least 20 feet away from the spray area An additional hose may be required Never place objects...

Page 6: ...from the air compressor either directly or from a breathing device connected to the air compressor Operate air compressor only in a well ventilated area Follow all safety instructions provided with t...

Page 7: ...restart at any time Do not operate without protective covers guards Replace damaged covers guards before using the air compressor Never allow children or adolescents to operate this air compressor St...

Page 8: ...ressor Pump 5 Safety Relief Valve 6 Air tank drain valve 7 Tank Pressure Gauge 8 Outlet Pressure Gauge 9 Pressure Regulator 10 Oil Dipstick 11 Oil Drain 12 Discharge Line 13 115 Volt Electric Power Co...

Page 9: ...tons move up and down in the cylinders On the downstroke air is drawn in through the air intake valves while the exhaust valves remain closed On the upstroke air is compressed the intake valves close...

Page 10: ...sary do not connect the grounding wire to either flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire WARNING This pr...

Page 11: ...less pressure and clockwise for more pressure 6 If you notice any unusual noise or vibration stop the air compressor and refer to Troubleshooting SHUTDOWN 1 To stop the air compressor move the lever...

Page 12: ...e Plug cord into grounded outlet Move switch to AUTO position Turn air compressor off wait until motor is cool then press motor thermal overload red button firmly until click is heard Replace fuse or...

Page 13: ...city of the air compressor Either use a smaller tool or a larger air compressor REMEDY Remove clean or replace REMEDY Replace REMEDY Operate safety relief valve manually by pulling on ring If it still...

Page 14: ...st pressure regulator knob to proper setting or replace Clean or replace Check for leaks and repair Replace with larger hose or connectors Check the accessory air requirement If it is higher than the...

Page 15: ...linder Steel sleeve inserts Valves Reed Single Head Aluminum Filter Canister Motor Pressure Switch Setting Cut out 116 PSI Cut in 87 PSI Controls Start stop Air tank Capacity 4 3 gallons Performance C...

Page 16: ...improper storage or damages resulting during shipping 4 Deviation from operating instructions specifications and maintenance schedules 5 Labor charges loss or damage resulting from improper operation...

Reviews: