background image

5

SAFETY WARNINGS

READ ALL SAFETY WARNINGS BEFORE USING AIR COMPRESSOR

POTENTIAL CONSEQUENCE

Serious injury or death may occur from
normal electrical sparks in motor and
pressure switch.

Serious injury may occur if any air
compressor ventilation openings are
restricted, causing the air compressor
to overheat and start on fire.

Serious injury or death may occur from
an air tank explosion if air tanks are
not properly maintained.

Serious injury may occur from an air
compressor malfunction or exploding
accessories if incorrect system
components, attachments or
accessories are used.

HAZARD

RISK OF

EXPLOSION OR FIRE

RISK OF

BURSTING

PREVENTION

Always operate air compressor in a
well ventilated area free of
flammable vapors, combustible
dust, gases or other combustible
materials.

If spraying flammable material,
locate the air compressor at least
20 feet away from the spray area.
(An additional hose may be
required.)

Never place objects against or on
top of air compressor. Operate air
compressor at least 12 inches away
from any wall or obstruction that
would restrict proper ventilation.

Drain air tank daily or after each use
to prevent moisture buildup in the
air tank.

If air tank develops a leak, replace
the air tank immediately. Never
repair, weld or make modifications
to the air tank or its attachments.
Use only genuine SENCO® repair
parts for your air compressor.

Never make adjustments to the
factory set pressures.

Never exceed manufacturers
maximum allowable pressure rating
of attachments.

Because of extreme heat, do not
use plastic pipe or lead tin soldered
joints for a discharge line.

Never use air compressor to inflate
small, low pressure objects such as
toys.

Summary of Contents for PC 2001

Page 1: ...r the safe use of this compressor are included in this manual PC 1001 Electric Air Compressor Document FN1001 Issued 5 30 A Questions Comments call SENCO S toll free Action line 1 888 222 8144 or e ma...

Page 2: ...5 BREATHING 6 BURNS 6 FLYING OBJECTS 6 MOVING PARTS 7 NEGLIGENCE 7 AIR COMPRESSOR DAMAGE 7 COMPRESSOR FEATURES 8 PREPARATION 10 INITIAL SET UP 10 LOCATION 10 ELECTRICAL 10 OPERATION 11 PRE START CHECK...

Page 3: ...ot avoided WILL result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury CAUTION Indicates a potentially hazar...

Page 4: ...electrical cords to lay in water or in such a position where water could come in contact with them Do not touch plug with wet hands Do not pull on the electrical cord to disconnect from the outlet Nev...

Page 5: ...ble dust gases or other combustible materials If spraying flammable material locate the air compressor at least 20 feet away from the spray area An additional hose may be required Never place objects...

Page 6: ...from the air compressor either directly or from a breathing device connected to the air compressor Operate air compressor only in a well ventilated area Follow all safety instructions provided with t...

Page 7: ...restart at any time Do not operate without protective covers guards Replace damaged covers guards before using the air compressor Never allow children or adolescents to operate this air compressor St...

Page 8: ...ressor Pump 5 Safety Relief Valve 6 Air tank drain valve 7 Tank Pressure Gauge 8 Outlet Pressure Gauge 9 Pressure Regulator 10 Oil Dipstick 11 Oil Drain 12 Discharge Line 13 115 Volt Electric Power Co...

Page 9: ...tons move up and down in the cylinders On the downstroke air is drawn in through the air intake valves while the exhaust valves remain closed On the upstroke air is compressed the intake valves close...

Page 10: ...sary do not connect the grounding wire to either flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire WARNING This pr...

Page 11: ...less pressure and clockwise for more pressure 6 If you notice any unusual noise or vibration stop the air compressor and refer to Troubleshooting SHUTDOWN 1 To stop the air compressor move the lever...

Page 12: ...e Plug cord into grounded outlet Move switch to AUTO position Turn air compressor off wait until motor is cool then press motor thermal overload red button firmly until click is heard Replace fuse or...

Page 13: ...city of the air compressor Either use a smaller tool or a larger air compressor REMEDY Remove clean or replace REMEDY Replace REMEDY Operate safety relief valve manually by pulling on ring If it still...

Page 14: ...st pressure regulator knob to proper setting or replace Clean or replace Check for leaks and repair Replace with larger hose or connectors Check the accessory air requirement If it is higher than the...

Page 15: ...linder Steel sleeve inserts Valves Reed Single Head Aluminum Filter Canister Motor Pressure Switch Setting Cut out 116 PSI Cut in 87 PSI Controls Start stop Air tank Capacity 4 3 gallons Performance C...

Page 16: ...improper storage or damages resulting during shipping 4 Deviation from operating instructions specifications and maintenance schedules 5 Labor charges loss or damage resulting from improper operation...

Reviews: