14
ENAMEL RATER MANUAL: V.10
3.
OPERATION
3.1
GENERAL DESCRIPTION
The will operate in two basic modes, "free run" and
"batch".
The free run mode includes reverse polarity operation, and is a
totally manual operation not using any of the automatic features or
interlocks of the . Although it can be used as an operating
mode on its own it is also available from within batch mode.
The normal operating mode is batch mode and this should be used
for rating cans even if a batch is not being tested.
All instructions assume the is initially in standby mode, i.e.
the milliamp display shows dashes and set to the factory
configuration given in Appendix A Fig 1.
3.2
CONFIGURATION CHECK
The Rating voltage and rating duration can be inspected whilst the
is in standby mode (i.e. the milliamp display shows
dashes) and before or after rating. To examine the rating voltage
and rating duration:
i.
Press the set key. The rating voltage is displayed on the
milliamp display. The
↑
and
↓
key are ignored.
ii.
Press the set key again. The rating duration is displayed
on the timer display. The
↑
and
↓
keys are ignored.
iii.
Press the End key. The drops back to the
condition it was in before the configuration check was
made.