ENAMEL RATER MANUAL: V.10
17
3.5
MASTER RESET
In the event of a major change, error or fault it may become
necessary to completely reset the instrument. This is always
required when the operating mode is changed.
A reset will erase all stored settings and reading from the units
memory.
To perform a master reset proceed as follows;
A)
Switch off power to the unit.
B)
Simultaneously hold down the SET,
↑
and
↓
keys.
C)
Switch on the power.
D)
After 2 seconds release the keys and the
system will be reset.
When a master reset is performed the operator has the opportunity
to change the default times and voltage settings (factory set to 4
seconds and 6.3V) using the SET,
↑
and
↓
keys. The new default
values are stored in battery backed memory and are retained until
another master reset is performed. The rating voltage and duration
can be checked during operation as described in Section 3.2.