Humidifier

User's manual

Prior to using this appliance, please read the user's manual thoroughly, even in cases, 

when one has already familiarised themselves with previous use of similar types of 

appliances. Only use the appliance in the manner described in this user's manual. Keep 

this user's manual in a safe place where it can be easily retrieved for future reference. 

We recommend saving the original cardboard box, packaging material, purchase 

receipt and responsibility statement of the vendor or warranty card for at least the 

duration of the legal liability for unsatisfactory performance or quality. In the event of 

transportation, we recommend that you pack the appliance in the original box from 

the manufacturer.

HOW THE HUMIDIFIER WORKS AND ITS FEATURES

   A  humidifier effectively increases indoor air humidity and thereby improves air 

quality and has a positive effect on human health. It acts preventively against drying 

out of the mucous membrane in the respiratory tract and prevents respiratory 

illnesses. Its use is recommended primarily during the heating season, when, as 

a rule, indoor air is predominantly dry.

   The SHF 2050BL / SHF 2051GR Humidifier works on the principle of a high frequency 

ultrasound oscillator. Thanks to this technology, it produces cold steam and does 

not affect the temperature in the room. The humidifying performance is adjustable 

and essential oils can be used to create a  pleasant indoor atmosphere. With 

a  humidifying performance of 250 ml/h, it is suitable for rooms up to an area of  

30 m

2

. Its large 4-litre water tank guarantees an operating time of up to 16 hours per 

single refill. When there is an insufficient amount of water in the tank, a signal is lit 

and, at the same time, a protective function is activated, which automatically shuts 

off the humidifier to prevent its damage. The automatic shut off is also activated, 

when the water tank is removed during operation.

DESCRIPTION OF THE HUMIDIFIER

A1

  Steam exhaust nozzle, 360° pivot 

A2

  Essential oil holder

A3

  Steam outlet

A4

  4-litre water tank 

A5

   Plug of the water tank filling 

opening with a water release switch

A6

  Water holder 

Water is pumped into the water 

holder from the water tank. 

A7

  Air exhaust opening

A8

 Nebulizer 

a surface where water is converted 

into cold steam (mist).

A9

  Base unit

A10

  Light indicator of operation and low 

water level in water holder 

A11

  Humidifying performance control 

serves to turn off the appliance  

and to set the output. 

A12

  Ventilation openings

OPERATING LOCATION OF THE HUMIDIFIER, ITS ASSEMBLY 

AND FILLING THE WATER TANK 

1.  Always place the humidifier on an even, dry and stable surface at a  minimum 

distance of:

  –  60 cm from the floor;

  –   30 cm from walls or sides of furniture;

  –   200 cm from electrical and electronic devices or materials sensitive to moisture 

to prevent their damage by the effects of increased humidity.

2.   Make sure that the humidifier is turned off and disconnected from the power socket. 

Remove the nozzle 

A1

 and lift the water tank 

A4

 off the base unit 

A9

. Turn it upside 

down and turn anticlockwise to unscrew the plug of the filling opening 

A5

 and 

remove it. 

3.  Fill the water tank 

A4

 with clean cold tap water. After filling up the water tank 

A4

properly secure the plug 

A5

 by turning it clockwise all the way. Turn the water tank 

A4

 upside down with the plug 

A5

 facing downwards and place it back on to the 

base unit 

A9

 so that both parts fit into each other properly. When the water tank 

A4

 

is placed on the base unit 

A9

, water will start to be pumped into the water holder 

A6

.

Attention:

 

The water tank 

A4

 is filled with water up to 40 °C. 

If you need to move the humidifier, be especially careful not to spill the 

water contained in the water holder 

A6

.

4.   After opening it, you may add a few drops of essential oil into the essential oil holder 

A2

 as shown in figure 

B1

. Before using any essential oils, please ask the vendor or 

an expert about its effects and correct dosage. Do not add anything other than 

essential oils to the essential oil holder 

A2

. After adding essential oil, close the 

essential oil holder 

A2

, see figure 

B2

.

5.  Place the nozzle 

A1

 into the steam outlet 

A3

.

USING THE HUMIDIFIER

1.  Check that the humidifier is correctly assembled. Connect the power cord to 

a power socket. Turn the control dial 

A11

 clockwise to turn on the humidifier. The 

indicator 

A10

 will be lit green. The humidifier will start producing cold steam within 

a  few moments. Ensure that during operation that the steam is not directed at 

furniture or items sensitive to moisture. The steam exhaust direction can be set by 

turning the nozzle 

A1

 to the required angle.

2.  Use the control dial 

A11

 to increase or decrease steam output intensity during 

operation. Turn the control dial 

A11

 clockwise to increase steam output, turn it in 

the opposite direction to reduce steam output. If you fill the water tank 

A4

 up to the 

edge, the expected operating time is up to 16 hours with the steam output set to 

maximum intensity.

Attention:

If the humidifier was transported at a  temperature below the freezing 

point, first put it into room temperature and wait approx. 30 minutes before 

turning it on.

Use the humidifier at an ambient temperature of 5 to 40 °C and at a relative 

humidity of up to 60 %. In the event that the ambient temperature falls 

below 0 °C, turn the humidifier off and remove the water inside the water 

tank 

A4

 and the water holder 

A6

, to prevent it from being damaged.

Do not lift the water tank 

A4

 out of the base unit 

A9

 or touch the nebulizer 

A8

 while the humidifier is running. For the event that the water tank 

A4

 is 

removed during operation, the humidifier is equipped with a  protective 

automatic shut off function.

3.   If the water level in the water holder 

A6

 runs low, the indicator 

A10

 will be lit red and 

the humidifier will automatically stop producing steam. This is a safety function to 

prevent the nebulizer 

A8

 from being damaged.

   If necessary, fill up the water according to the instructions in point 2 and 3 in chapter 

Operating location of the humidifier, its assembly and filling the water tank. Then 

you can start the humidifier again.

4.  To turn off the humidifier, turn the control dial 

A11

 anticlockwise all the way. The 

indicator 

A10

 will turn off. Disconnect the humidifier from the power socket and 

clean it out according to the instructions contained in the chapter Cleaning and 

maintenance.

CLEANING AND MAINTENANCE

   Before cleaning the humidifier, turn it off and disconnect it from the power socket.

   Please adhere to the following instructions relating to the cleaning and maintenance 

of the humidifier. Otherwise its performance may be negatively affected and 

undesirable microorganisms may multiply inside the humidifier.

Clean after every use

   Remove the nozzle 

A1

 from the steam outlet 

A3

. Then take out the essential oil 

holder 

A2

 and clean out any remaining essential oil, and then put it back in its place. 

Take the water tank 

A4

 off the base unit 

A9

, carry it to a kitchen sink, turn it upside 

down and open the lock 

A5

. Remove any remaining water from it via the filling 

opening, rinse it out with clean water and dry the surface using a fine wiping cloth. 

Finally, attach the lock 

A5

 to the water tank 

A4

, and insert the nozzle 

A1

 into the 

outlet 

A3

.

   Remove the water from the water holder 

A6

 and wipe it dry using a fine clean cloth.

Thorough cleaning (once per week)

   Pour approximately 100 ml of vinegar into the water holder 

A6

 and allow it to act for 

15 minutes. Using a brush with gentle bristles, remove the limescale deposits in the 

water holder 

A6

 and the nebulizer 

A8

. Then clean out all the remaining limescale 

and vinegar using a cloth dampened in clean water and wipe dry.

   Thoroughly clean out the essential oil holder 

A2

 under running water or using 

a dampened cloth and then put it back in its place.

Attention:

Do not leave water in the water tank 

A4

 or in the water holder 

A6

 for longer 

than a week. 

Do not touch the nebulizer 

A8

 with sharp objects in order not to damage it.

   Clean the outer surface of the humidifier as required using a fine clean cloth lightly 

dampened in lukewarm water.

   Do not submerge the base unit 

A9

 in water or rinse it under running water. For 

cleaning, do not use abrasive cleaning products, solvents, etc. Otherwise, this could 

damage the surface of the appliance.

TROUBLESHOOTING

Problem

Possible cause

Solution

The indicator light 

A10

 is not lit and 

the humidifier is not 

producing steam.

The humidifier is 

connected to a faulty 

power socket or is not 

connected to a power 

socket at all.

Connect the humidifier to 

a working power socket and use 

the control dial 

A11

 to set the 

required steam output intensity.

The indicator light 

A10

 is lit red.

There is not enough 

water in the water 

holder 

A6

.

Turn off the humidifier and 

disconnect it from the power 

socket. Fill up the water tank 

A4

 

with cold clean water. Assemble the 

humidifier, connect it to a power 

socket and start it again.

An odour can be 

sensed in the steam.

The odour may be 

sensed when the 

humidifier is used for 

the first time.

Open the water tank plug 

A5

 and 

allow the water tank 

A4

 to ventilate 

for at least 12 hours.

There is dirty water in 

the water tank 

A4

 / 

water holder 

A6

.

Turn off the humidifier and 

disconnect it from the power 

socket. Remove the water from 

the water tank 

A4

 and the water 

holder 

A6

. Clean everything. Fill up 

the water tank 

A4

 with cold clean 

water. Connect the humidifier to 

a power socket and start it again.