66
13 Operation
13.1 Front display operation
OK
ESC
Passiv
Laden
Entladen
Störung
The front display shows the status, the IP address, the battery voltage, the
charge and discharge current and the PV output.
OK
ESC
Passiv
Laden
Entladen
Störung
OK
ESC
Passiv
Laden
Entladen
Störung
Switching on:
Press the On/Off button.
The SENEC.Home Li now switches the SENEC.Inverter on.
Confirm with OK.
Switching off:
Keep the On/Off button pressed for several seconds.
The
display shows “Switch off?”.
Press the OK button within 15 seconds.
The SENEC.Home Li now switches
the SENEC.Inverter off. The status changes to Switched off.
13.2 IP address in the front display
The current IP address of the SENEC.Home Li is shown in the front display. It provides information concerning
how the storage unit is connected to the network.
IP address
Explanation
192.168.168.2
During start sequence
192.168.xxx.xxx or 10.xxx.xxx.xxx
SENEC.Home Li is connected to the customer's
network (e.g. behind a Fritz!Box router or pro-
fessional network)
255.255.255.255
Network error
13.3 MCU blink codes
The MCU has four LEDs. These provide information regarding the status of the software in the SENEC.Home
Li. The LEDs flash green. “x” means flashing, “o” means “inactive/not flashing”.
LEDs on the MCU (from top to
bottom)
Meaning
x o x o
Firmware update in progress (approximately 30 seconds)
x o x o alternating with o x o x
SD card faulty in attempt to run a firmware update
x x o o
SD card faulty (display: SD card fault)
x x o o alternating with x x x x
Software is running normally