background image

MI001943-E

ENGLISH - 8/9

SENECA s.r.l.

Via Austria, 26 - 35127  -  PADOVA - ITALY

Tel.  +39.049.8705355 - 8705359  -  Fax +39.049.8706287
e-mail: info@seneca.it  -  www.seneca.it

This document is property of SENECA srl. Duplication and reproduction are forbidden, unless authorized.
The contents of this document refer to the products and technologies described in it. All the technical data
contained in this document is subjected to periodical revision and may be modified without prior notice.

Disposal of Electrical & Electronic Equipment (Applicable within the European Union and other countries
with separate waste collection procedure).
This symbol, found on your product or on its packaging, indicates that this product should not be
disposed of as household waste. Instead, it should be handed over to an authorised collection point for
the recycling of electrical and electronic equipment. By ensuring that this product is disposed of

correctly, you will help prevent potential negative consequences for the environment and human health,
m which could otherwise be caused by inappropriate disposal of this product. The recycling of materials
will help to conserve natural resources. For more detailed information about the recycling of this
product, please contact your local city office, waste disposal service or the retail store where you
purchased this product.

Size and dimension

Summary of Contents for S315

Page 1: ...Page General characteristics 2 Installation instructions 4 Electrical connections 4 Parameter menu 5 Types of errors 6 Menu parameter modification 7 Parameter configuration example 8 Position of buttons and terminals 8 Programming menu diagram 9 Dimension and size 10 Disposal 10 ENGLISH 1 9 Installation manual E 4 digit display loop powered digital panel indicator ...

Page 2: ... displayed on the 4 digit display S315 provides excellent resolution high accuracy and temperature stability The instrument is compact size Power supply from measure loop Current 4 20mA Input oop voltage drop Max 7 5 V L ADC 16bit 30V Max Measure loop powered navigation on the programming menu using the three buttons Easy on front panel the P65 wit the provided seal Protection index I h Input para...

Page 3: ...rferance 1 ENVIRONMENTAL CONDITION Operating temperature 20 65 C Storage temperature 30 85 C Humidity 30 90 non condensing Altitude Up to 2000 m above the sea level CONNECTION Terminal block 2 way removable screw terminals 5 08 mm pitch CASING Size L xW x H Weight Protection index Case material 96 x 48 x 40 mm 200 g IP 65 Plastic NORMS STANDARDS Standards MI001943 E ENGLISH 3 9 ...

Page 4: ...l point 1 one decimal point 2 two decimal points 0 No filter 1 5 Active Adds an offset Default settings 1 Ovenwrite the set parameter with default value and exit from menu Exit from menu By confirming with all the set OK MENU parameters will be saved on a flash memory The module is ready for use with the new setting without the need for restart Integer values between minimun and maximum Parameter Func...

Page 5: ... lower than the set B The tha value n to be s own is ower h l MI001943 E ENGLISH 5 9 4 20mA 2 1 Electrical connections CURRENT SUPPLY AND MEASURE Installation instructions The is des gned to insta ed in the electrical switchboard n order to ensure module be i ll I optimum performance and the longest working ife the module s be supplied with l must adequate ventilation Do not install the module abo...

Page 6: ...rameter Increases the value by o e it n un Decrease the value by one unit Confirms the value and moves the next to At the last digit press once to confirm the value and press again to return to the parameter just set Value setting notes Negative va ues l in the last field it is also possible to enter a sin or a value of 1 NOTES ANY VALUES ENTERED OUTSIDE THE RANGE ARE AUTOMATICALLY BROUGHT BACK WITHI...

Page 7: ...99 Access DOWN MENU OK for 3 seconds until menu the menu by pressing DOWN appears is the password to lf necessary Press after entering display the next submenu Access the menu and set F 9 or a complete map of the programming menu see page Position buttons and terminals REAR REMOVABLE SCREW TERMINALS FRONTA BUTTONS L MI001943 E ENGLISH 7 9 ...

Page 8: ...separate waste collection procedure This symbol found on your product or on its packaging indicates that this product should not be disposed of as household waste Instead it should be handed over to an authorised collection point for the recycling of electrical and electronic equipment By ensuring that this product is disposed of correctly you will help prevent potential negative consequences for ...

Page 9: ...Programming menu diagram E Esquema del menú de programación S F Schéma du menu de programmation Premere i due tasti contemporaneamente per alcuni secondi ACCESSO AL MENÙ DI PROGRAMMAZIONE ACCESO AL MENÚ DE PROGRAMACIÓN Mantenga presionados los dos botones al mismo tiempo durante 3 segundos Push the two buttons at the same time for 3 seconds ACCESS TO THE PROGRAMMING MENU ACCÈS AU MENU DE PROGRAMMA...