background image

ENGLISH - 2/8

t

STANDARDS

EN61000-6-4

Electromagnetic emission, industrial environment

.

EN61000-6-2

Electromagnetic immunity, industrial environment.

.

EN301 511

Harmonized standard for mobile stations

.

EN301 489-1

ElectroMagnetic Compatibility for radio equipment

.

EN301 489-7

Specific (EMC) conditions for mobile radio equipment

EN60950

Safety of information Technology Equipment.

INSULATION

ENVIRONMENTAL
CONDITIONS

Temperature
Humidity
Storage temperature
Protection rating

0    + 50°C / (-10    + 40°C with internal UPS use).

30% –

t

ing.

90% no  condens

-20    + 65°C / (-20    + 45°C < 6

with internal UPS use).

months

IP20.

MOUNTING

35mm IEC EN60715 DIN Rail.

INTERNAL UPS

Backup rechargeable batteries, NiMH

CONNECTIONS

Removable

three pole screw terminal pitch 5mm

, for cable up to 2.5 mm ,

2

rear IDC10, front RJ45, Micro USB and Antenna SMA.

POWERSUPPLY

Voltage
Power absorbed

11 – 40 V or 19 – 28 V

. P. max

C

C

50 60 Hz

< 6.5W.

If the voltage is lower than 12 V, the internal UPS battery can' t be
recharged.

DIGITAL INPUTS

Number of channels 4. PNP or NPN configurable.
Input voltage OFF<4V ON>8V (Max. 24V ). Input current 20mA.

C

Max. frequency 30Hz. Absorbed Current 3mA @ 12V

10mA @ 24V .

C

C

TOTALIZERS

Four 32 bit totalizers on non-volatile memory.

COUNTERS

Four 32 bit resettable counters on non-volatile memory.

DIGITAL OUTPUTS

Number of channels

SPDT Relays with free contacts.

2.

Max. Voltage 250V . Max. Current 2A.

A

ANALOG INPUTS

Number of channels 2. mA

or V

configurable.

C

C

Voltage input 0 – 30V. accuracy 0.1% of the Full Scale.
Current input 0    20mA

accuracy 0.1% of the Full Scale.

Inputs protection 40V / 25mA. Resolution 16 bit.

COMMUNICATION
PORTS

Rear RS485 COM1 port. RS485 or RS232 M10-M11-M12 COM2 screw
terminals port. Ethernet 10/100 baseT RJ45 frontal port with autoswitch.
MicroUSB side port.

TECHNICAL SPECIFICATIONS

Communication

Power

Supply

Input

Output

1500 V

~

3 0  V

00

~

USB

RS485

RS485

RJ45

DI 1

DI 2

DI 3

DI 4

AI 1

AI 2

DO 1

DO 2

Summary of Contents for Z-GPRS3 HW2

Page 1: ...bed in it This informations may be modified or integrated for technical and or commercial requirements SENECA s r l Headquarters Via Austria 26 35127 PADOVA ITALY Phone 39 049 8705355 8705359 Fax 39 0...

Page 2: ...V or 19 28 V P max C C 50 60 Hz 6 5W If the voltage is lower than 12 V the internal UPS battery can t be recharged DIGITAL INPUTS Number of channels 4 PNP or NPN configurable Input voltage OFF 4V ON...

Page 3: ...thout any interruptions for at least 72 hours in order to charge the internal batteries Disposal of electrical electronic equipment applicable throughout the EU and other countries with separate colle...

Page 4: ...ear IDC10 connector into a free slot of DIN rail accessory as you can see in fig 1a the insertion is one way only because the connectors are polarized 3 To secure the module to the IEC EN 60715 DIN ra...

Page 5: ...r between 19 and 28 V C A The power supply source must be protected from any malfunctions of the module through appropriately sized safety fuse 2 ANALOG INPUTS Voltage Current active sensor 4 fili Cur...

Page 6: ...e not used Fast Blinking 0 2s ON 0 2s OFF n o nononononononono RS485 or RS232 communication Timeout GSM Yellow Blinking 64ms ON 3s OFF n o noooooooooooooooooooooooo Connected to the GSM network Blinki...

Page 7: ...ct 4 PWR STS Green ON n Z GPRS3 ON inactive log status ready Slow Blinking 2 8 sec ON 0 4 sec OFF nnnnnnnnnnnnnnoo Z GPRS3 active log status normal Slow Blinking 1 6 sec ON 1 6 sec OFF nnnnnnnnooooooo...

Page 8: ...I D 3 I D 2 I DI1 ETH LNK ETH ACT SD PWR ETHERNET ANTENNA Z GPRS3 19 20 21 22 23 24 micro USB micro USB 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 S SENECA ETH USB GSM 485 ACT DO2 D 1 O The module has a R...

Reviews: