Output Connection

Input for In < 10 A 

 Input for In < 5 A

Applied Current

Input Connection

7

 

8

 

In

 

7

 

9

 

In

 

ELECTRICAL CONNECTIONS

We  recommend  using  shielded  cables  for  signal  connections;  the  shield  must  be 
connected  to  a

  instrument

  earth  connection.  We  also  recommend  never  positioning 

these  wires  near  power  cables  such  as  those  for  inverters,  motors, or induction ovens, 
etc.

Power Supply Connection

The power supply voltage must be in the range of  85

-

265 V

AC/VDC

.

The upper limits must not be exceeded as this can seriously damage the module

.

 

The power supply source must 

include a fuse or suitable limiting device to 

protect from any 

failures in the module.

 

 

6

5

V

4

5

5

ext. supply

max 28 V

6

A

A

Voltage 

    

External Power Supply

When connected to a 

current tra

nsformer, 

one of the two wires 
must be grounded.

Power supply

1

3

85

-

265 V

DC/AC

 

50

-

400

 

Hz

Max 2 W

Disposal  of  Electrical  &  Electronic  Equipment  (Applicable  throughout  the  European  Union  and  other 
European countries with separate collection programs)
This symbol, found on your product or on its packaging, indicates that this product should not be treated as 
household waste when you wish to dispose  of  it. Instead, it should be handed over to an  applicable 
collection  point  for  the  recycling  of  electrical  and  electronic  equipment.  By  ensuring  this  product  is 
disposed of  correctly, you will help prevent potential negative consequences  to  the  environment and 
human health, which could otherwise be caused by inappropriate disposal of this product. The recycling of 
materials will help to conserve natural resources. For more detailed information about the recycling of this 
product,  please  contact  your  local  city  office,  waste  disposal  service  or  thè  retail  store  where  you 
purchased this product.

SENECA s.r.l.

Via Austria, 26 - 35127  -  PADOVA - ITALY
Tel.  +39.049.8705355 - 8705359  -  Fax +39.049.8706287
e-mail: info@seneca.it  -  www.seneca.it

This document is property  of SENECA srl. Duplication and reprodu

c

tion are forbidden, if not authorized. Contents of 

the  present  documentation  refers  to  products  and  technologies  described  in  it. All  technical  data  contained  in  the 
document may be modified without prior notice

.

 Content of this documentation is subject to periodical revision.

Summary of Contents for Z201-H

Page 1: ...ent converter measures the simple harmonic alternating current applied at the input and generates a standard mA or V signal directly proportional to the current measured BLOCK DIAGRAM INPUT OUTPUT CAT III 300 V TECHNICAL SPECIFICATIONS Power Supply Consumption Current Input 85 265 VDC or VAC from 50 to 400 Hz Isolation input output 4000 VAC 2 W at full load 20 mA 230 VAC Power Supply Specification...

Page 2: ... variation max 100 ms from 10 to 90 Temperature 10 to 65 C humidy 30 95 40 C not condensing Group III Storage Temperature 20 to 85 C Altitude up to 2000 meters a s l Presence of power supply green IP20 140 g 100 x 112 x 17 5 mm 1 These acronyms apply om of measurement ots of the scale 2 Error caused by electromagnetic disturbances EMI 3 The precision values are indicated for a sinusoidal signal wi...

Page 3: ...NAL JUMPER POSITION OUTPUT SIGNAL SETTINGS The Z201 H instrument transmits a voltage or a current signal The output type voltage or current is set using the internal jumper accessible under the rear side of the the case The signal range is set using the double DIP switch SW1 Current or Voltage Output Selection Current Output F Voltage Output SW1 SW1 J1 J1 Output Range Settings Switch 1 Position Sc...

Page 4: ...tecollectionprograms Thissymbol foundonyour product oron itspackaging indicatesthat thisproductshould notbetreatedas household waste when you wish to dispose of it Instead it should be handed over to an applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences to the e...

Reviews: