SenNet CO2-TH Sigfox 

 

www.satel-iberia.com 

 

Secuence of messages: 

 

 
Downlink Message 

It’s possible set the device 

in the cloud without interacting with it locally, defining this type of downlink message 

and CT value on the sigfox backend or in your platform

. That method is optional but it’s not 

necessary. 

 

Byte 

2 - 5 

Field 

Easy Meter Setup byte 
(1byte) 

Not used 
(4 bytes) 

Type uplink 
Message 
(1 byte) 

Interval to 
send 
(minutes) 

Not 
Not 
used 

Value 

Bit 7 

1     (by default) 

0x00 0x00 
0x00 0x00 

01 

[10…59]

 

0x00 

Bit 6 

0     (by default) 

Bit 5 

1/0  enable/disable set Type uplink Messsage 

Bit 4 

1/0  enable/disable set Interval to send 

Bit 3 

0     (by default) 

Bit 2 

0     (by default) 

Bit 1 

0     (by default) 

Bit 0 

0     (by default) 

 

Example for downlink message: 
 

90 00 00 00 00 01 0F 00

   

 With this downlink message setup interval to send to 15minutes. 

 
   
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 

Power on

Message type 0

ask for Donwlink message for 

remote settings

Message 

type 1 or 2

Message 

type 1 or 2

Summary of Contents for IoT CO2-TH Sigfox

Page 1: ...C power Wired Setup Reference Power supply type CO2 TH Sigfox bat Battery 3 6v 18000mAh LS26500 x2 CO2 TH Sigfox AC AC Power supply 100 265Vac Basic steps to intall 1 Set interval to send by default 15 minutes 2 Take note ID PAC to sign the device on Sigfox Cloud 3 Plug in pack batteries or AC power supply Setup parameters methods Throught donwlink message see donwlink message seccion recommend me...

Page 2: ...ge by customer requeriment wall mount by default rail din mount accesory specify on your order Battery life estimation 10 minutes sends 2 years 20 minutes sends 5 years 30 minutes sends 7 years Holding case IP Grade IP 60 Temperature details Working temperature 20ºC 70ºC Store temperature 20ºC 75ºC Holding Dimensions 119 x 111 x 53 mm Type mount Wall or din rail Plastic Material ABS V0 If you need...

Page 3: ... not defined Low level Battery Internal Error CO2 sensor Downlink error Not used Not used Feedback Error Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Byte1 Bit 7 6 5 Byte1 Bit 4 3 2 1 Byte1 Bit 0 Byte2 Bit 7 6 Byte2 Bit 5 4 3 Byte2 Bit 2 1 0 Table 1 First message after power on the device is debug message with internal information about build firmware This message must be not parser by client platform and ...

Page 4: ...ot used 4 bytes Type uplink Message 1 byte Interval to send minutes Not Not used Value Bit 7 1 by default 0x00 0x00 0x00 0x00 01 10 59 0x00 Bit 6 0 by default Bit 5 1 0 enable disable set Type uplink Messsage Bit 4 1 0 enable disable set Interval to send Bit 3 0 by default Bit 2 0 by default Bit 1 0 by default Bit 0 0 by default Example for downlink message 90 00 00 00 00 01 0F 00 With this downli...

Page 5: ...hat exceeds the limits indicated in this manual Satel Spain declines all responsibility for possible damage to the equipment or to other parts of the installations and will not cover possible penalties derived from a possible breakdown poor installation or misuse of the equipment Consequently the guarantee is not applicable to breakdowns produced in the following cases Due to overvoltage and or el...

Reviews: