3.0 Setup
37
© 2020 Sensata Technologies
3.3.5 TECH
Menu
The TECH menu button provides access to selections that are used to
assist service technicians in troubleshooting. It provides access to system
information along with a selection that allows all system settings to be
returned to the original factory default values.
• TECH: 01 Temperatures
– Displays the various temperatures
measured throughout the system. Rotate the SELECT knob to scroll through
these temperature readings. The following read only temperature displays
are available:
BTS:
Displays temperature of the inverter’s Battery Temp Sensor (BTS)—if
one is connected to the battery bank.
Tfmer:
Displays temperature of the main power transformer (Tfmer) inside
the inverter.
FETs:
Displays temperature of inverter’s Field Effect Transistors (FETs).
AGS:
Displays the temperature of the AGS (Auto Generator Start) temp
sensor—if one is connected. If no AGS is connected, “
No Comm
” displays.
TECH
Press
Status...
01 Temperatures
Rotate to
Press to select
Rotate to
desired
display:
Options: BTS:, Tfmer:, FETs:, AGS:
Figure 3-22, TECH: 01 Temperatures Display
• TECH: 02 Revisions
– Displays the
fi
rmware revisions of the devices
that are connected to the Magnum network. Rotate the SELECT knob to scroll
through the revisions. The following devices display revisions (if connected
to the remote): Inverter, Remote, AGS, BMK, and Router.
TECH
Press
Status...
02 Revisions
Rotate to
Press to select
Rotate to
desired
display:
Options: Inverter:, Remote:, AGS:, BMK:, Router:
Figure 3-23, TECH: 02 Revisions Display
Info:
The BMK, AGS, and the remote accessories may display a
“0.0”
revision. If this happens, then the accessory is not installed,
there is no communication because of a bad or miswired network
cable, the device is not powered, the device is bad, or the port on
the inverter is bad.