5.0 Operation
57
© 2020 Sensata Technologies
LED
Status
Meaning
PWR
(green)
OFF
1. Inverter is disabled; 2. Remote is in Power
Saver mode – press any button to activate LEDs;
3. No power to remote (check remote cable or
power to inverter); or, 4. No AC power at the
inverter’s AC output terminals.
ON
AC power is available from inverter, shore, or
generator at the inverter’s AC output terminals.
FAULT
(red)
OFF
Normal operation.
ON
A fault condition has been detected. Check the
LCD display to
fi
nd and correct the cause.
CHG
(green)
OFF
1. Remote is in Power Saver mode – press any
button to activate LEDs; or, 2. Charger off – no
utility or AC generator present.
ON
Bulk, Absorb, Float, or Equalize Charge mode (see
LCD display to determine charge status).
BLINKING,
display says
“
Charger
Standby
”
The charger is in Charger Standby mode. This
occurs when the ON/OFF CHARGER button is
pressed to disable the charger.
BLINKING,
display says
“
Full Charge
”
or “
Silent
”
The charger is in Battery Saver mode. This mode
monitors battery voltage level and only charges if
the battery voltage decreases to a low level. Silent
mode will automatically start charging when the
Rebulk
setting is reached.
BLINKING,
display shows
a charging
status (i.e.,
Bulk, Absorb,
Float)
The charger current is automatically decreased
because: 1. Charger Back-off – the inverter’s
internal temperature is getting hot, current is
decreased to reduce/maintain temperature; or, 2.
Low AC Input Voltage – the input AC voltage is
low, charger is disabled to help stabilize incoming
AC voltage to prevent AC disconnect.
BLINKING,
display does
not
show any
charge status
The inverter is detecting AC voltage (from utility
or an AC generator) on the inverter’s AC input
terminals.
INV
(green)
OFF
1. Inverter disabled; or, 2. Remote in Power Saver
mode – press any button to activate LEDs.
ON
Inverter is enabled – 1. Supplying AC power on the
output; or, 2. In Inverter Standby (if both INV and
CHG LEDs are on); the inverter will automatically
supply AC power to the loads if shore or generator
power is lost.
BLINKING
Inverter is in Search mode (the AC load is below
the SETUP menu’s
01 Search Watts
setting).
5.3.4 LED Indicator Guide
Use the LEDs along with the LCD display to determine the operating status.
Table 5-1, LED Indicator Guide