background image

The  KFT-2410R supply was designed for industrial
installations where operation is continuous and requires
reliable components.
Built with the most modern techniques of switching with high
performance and small footprint supplys, and excellent
stabilization and regulation.

Supply Fixing:

Fixing the supply internally in the
panel must be made using 35mm
rails (DIN-46277).
Follow the procedures below:

1° Place only the supply upper
bracket on the rail . (Fig.03)

2 º Lower the supply   until it fully
engages on the rail. (Fig. 04).

3º We recommend installing stops
so that the supply does not slide on
the rail. (Fig 05).

Horizontal mounting:

We recommend mounting in a
horizontal position in order to
ensure improved air circulation and
that the panel is provided with a ventilation system to prevent
overheating of the internal components.

Note:

 We recommend also leaving a gap of at least 20mm

from one supply to another, in order to improve the cooling.

Electric Installation:

The supply has 9 terminals according to the table below:

Terminal

       Description

1 and 2

Positive output 24 Vdc

3 and 4 

Negative output 24Vdc

5 and 6

  Alarm

7 and 9

  AC input

8

Ground

Wire Preparation:

Do the ends of the wires according to the drawing below:
 Be careful when removing the protective cover not to make
small cuts in the wires, as this may cause short circuit.

Note:

 The minimum wire size for an output current of 10A must

be 1mm

2

.

Procedures:

Remove the protective cover, insert the terminals and crimp
them. If you want to tin the ends for better grip.

Terminals:

To avoid problems of poor contacts and shorting advise using
pre-insulated terminals crimped on the wires.

AC input:

The  KFT-2410R power supply has an automatic selection
circuit for 110 or 220Vac (full range), which prevents damage
to the supply with the improper selection / connection of the
equipment.

Voltage

Power

Current

110 Vac

187 VA

1,7 A

220 Vac

220 VA

1 A

Note

: The values shown in the table above are for the condition 

of maximum load (10A) in the supply.

AC Input Protection:

We recommend using the electrical circuit that supplies the
unit by a protection circuit breaker or fuse.

Supply Terminals:

• Loosen the terminal screw using a switch with a diameter of

3 to 3,5mm.

• Insert  the  wire  with the terminal already applied, from the

bottom of the terminal.

• Tighten  the terminal screw, and repeat for the other

terminals.

• Verify that actually wires are securely attached by pulling

them lightly.

Output Voltage:

The unit has a stabilized output voltage regardless of the
current drawn.
The  direct current output, positive  (1 or 2) and negative (3 or
4) terminals of the unit provides 24VDC with capacity for up to
10A.
We recommend its use for  automation circuits supply such as:
electronic sensors
PLC input or output cards.
electronic modules
auxiliary relays
Current loops

• Industrial networks Profibus DP and DeviceNet standards

Signalling Led:

The supply has on its front a two-color LED whose function is
described in the table below:

Led Status

Function

Green on

Normal operation 

Green off

stand by

Red on

Short-circuit or overload

Note:

 The  standby condition (sleep) occurs when the supply is 

working in parallel with each other and with lower output
voltage than other supplys, and this condition does not provide
(splits) current to the load.

Rua Tuiuti, 1237 - CEP: 03081-000 - São Paulo

Tel.: 11 2145-0444 - Fax.: 11 2145-0404

vendas@sense.com.br - www.sense.com.br

 INSTRUCTIONS MANUAL 

Switching Power Supply

KFT-2410R/110-220Vac

Tab. 8

Fig.7

  1 2 3 4  5 6

   7 8 9 

Fig. 1

Pic. 2

Alicate ZA3

Pic. 10

Pic. 11

   +

   -

5

F

110 ou 
220Vca

 F

 N

40

5

Pic. 9

Fig. 3

Fig. 4

Fig. 6

FONTE DE ALIMENTAÇÃO

LED

F

F

N

CORRENTE ALTERNADA

110 ou 220Vca

EM

ENTRADA

CORRENTE CONTINUA

SAÍDA

-

+

24Vcc

-

+

ALARME

Fig. 5

EA3000830- Rev. Bi - 09/15

2

1 .

b

a

T

Pic. 13

Fig. 14

Fig. 15

Fig. 16

Tab. 17

Reviews: