Manual
Unit
5.2.3 CRIMPING
The sensor cable is connected to circuit boards using CLB2 female crimp connectors. The connectors
are crimped with a LIST crimping tool (Refer to the crimping tool manual for further information)
Crimping procedure:
1.
LIST crimping tool:
Deactivate both outer press plates by
moving these to the top of the tool.
2. CLB2 female crimp connector:
Open the lid of the CLB2 connector so that the contacts are exposed.
Insert the CLB2 from the side of the tool.
Both contacts must must be positioned over the two middle fingers
of the anvil.
3. Insert sensor cable:
Fully insert the flexible cable into the
CLB2 contacts.
4. Crimping:
Close the crimping tool completely by pressing
the tool handle.
The ratchet releases automatically, once the tool is fully closed.
5. Close the CLB2 lid
Page 24/44
LISTEC GmbH
60T023-04 / 30.04.2014