17
Section 3
CamCor CT and PRO Series Hardware Manual
Low-Temperature Models (CC025 through CC250)
Item
Description
Model
CC025
CC040
CC050
CC080
CC100
CC150
CC15H
CC200
CC20H
CC250
Nominal size
25 mm,
1˝,
DN25
40 mm,
1-1/2˝,
DN40
50 mm,
2˝,
DN50
80 mm,
3˝,
DN80
100 mm,
4˝,
DN100
150 mm,
6˝, DN150
200 mm,
8˝, DN200
250 mm,
10˝,
DN250
Materials
Wetted parts
SUS316L, Alloy C22
SUS316L
Housing
SUS304
Process connection
ASME 150, 300, 600, 900
RF;
DIN PN 10, 16, 25, 40 RF
; IDF Ferrule
ASME 150, 300, 600 RF;
DIN PN 10, 16, 25, 40 RF
ASME 150, 300 RF;
DIN PN 10, 16, 25, 40 RF
Applicable fluids
Liquid and gas
Liquid
Density range
0.3 to 2.0 g/mL
Temperature range
–328°F to 122°F
Tube withstand @ 100
°
F
1520 psig
1924 psig
1551 psig
1300 psig
Maximum operating pressure
Dependent on flange rating
Sensor housing withstand
232 psig
261 psig
203 psig
—
Flow direction
Bi-directional
Explosion-proof configuration
CSA, ATEX, and IECEx (Refer to
Section 10—Explosion-proof Specifications, page 113
for details.)
Dust-tight, waterproof configuration
IP66/67
1. When SUS316L is selected as the wetted parts material, the flange material will be dual-rated SUS316/SUS316L.
2. DIN flanges are only available for meter material SUS316L.
3. ASME 900 flanges are only available in Alloy C22 material.
4. For application with foods, this product does not comply with CE marking.
5. This pressure does not represent the rated test pressure of a pressure vessel. It represents 1/4 of the factory-tested breakdown pressure or the data obtained from FEA
analysis, whichever is lower. Distorted enclosures do not constitute a failure of the test.
* Only available with separately-mounted transmitter and interconnect cable (ordered separately; 10-meter minimum, available in 5-meter increments thereafter).
* For products conforming to the high-pressure gas safety regulations and CE marking, consult Cameron.
PRO SERIES SENSOR GENERAL SPECIFICATIONS
Item
Description
Model
CP006
CP010
CP015
CP025
CP040
CP050
Nominal size (in.)
1/2
1/2
1/2
1
1-1/2
2
Materials
Wetted parts
SUS316L
Housing
SUS304
Process connection
ASME 150, 300, 600 RF; IDF Ferrule; Threaded (CP006, CP010 and CP015 only)
Applicable fluid
Liquid
Density range
0.3 to 2.0 g/mL
Temperature range
–40°F to 257°F
Maximum operating pressure
Dependent on process connection
Flow direction
Bidirectional
Explosion-proof configuration
CSA, ATEX, and IECEx (Refer to
Section 10—Explosion-proof Specifications, page 113
Dust-tight, waterproof configuration
IP66/67
1. Refer to
Section 10—Explosion-proof Specifications, page 113
. In case of non-explosion-proof model, up to 257˚F is permitted. However, the product must be used within
the maximum ambient temperature of 113˚F.
2. Cleaning in place (CIP) is permitted within the temperature range.
Summary of Contents for CamCor CC001
Page 14: ...14 CamCor CT and PRO Series Hardware Manual Section 3 This page is left blank intentionally ...
Page 24: ...24 CamCor CT and PRO Series Hardware Manual Section 3 This page is left blank intentionally ...
Page 54: ...54 CamCor CT and PRO Series Hardware Manual Section 5 This page is left blank intentionally ...
Page 62: ...62 CamCor CT and PRO Series Hardware Manual Section 7 This page is left blank intentionally ...