Table 3.1—Configured Units
Register
(Decimal)
Register
(Hex)
Description
Units
Data
Type
Data Range
Access
38
0026
Mass Flow Rate Unit
see
U8
RW
39
0027
Volume Flow Rate Unit
40
0028
Density Unit
41
0029
Temperature Unit
Density Configuration
Register
(Decimal)
Register
(Hex)
Description
Default
Data
Type
Data Range
Access
154
009A
Density Override Setting
U8
0 = Disable
1 = Enable
RW
155
009B
Density Override Value (g/ml)
FP
0.0000 – 5.0000
RW
168
00A8
Density Compensation
0
U8
0 = Disable
1 = Enable
RW
169
00A9
Base Temperature (°C)
FP
–999.99 to 999.99
RW
171
00AB
ExpASMEon Factor
0.00024
FP
–999999 to 999999
RW
Alarm/Status Configuration
Register
(Decimal)
Register
(Hex)
Description
Default
Data
Type
Data Range
Access
137
0089
Analog Output Error Setting
1
U8
0 = Upscale
1 = Downscale
2 = Hold
3 = Zero (4 mA)
RW
138
008A
Pulse Output Error Setting
3
U8
0 = Upscale
2 = Hold
3 = Zero (0 Hz)
RW
139
008B
High/Low Alarm Check Setting
0
U8
0 = High Alarm Check
1 = Low Alarm Check
2 = High and Low
Alarm Check
RW
140
008C
High/Low Alarm Unit
see
U8
RO
141
008D
High Alarm Set Point
FP
–999999 to 999999
RW
143
008F
Low Alarm Set Point
145
0091
High/Low Alarm Deadband
147
0093
Status Input Function Setting
250
U8
0 = 0% Signal Lock
1 = Auto Zero Adjust
2 = Reset All Flow
Totals
3 = Reset Flow Total 1
4 = Reset Flow Total 2
250 = No Function
RW
148
0094
Status Output Function Setting
250
U8
0 = Error Status
1 = Bidirectional
2 = High/Low Alarm
Setting
3 = Drive Out Alarm
250 = No Function
RW
16
Section 3
CamCor
™
Modbus Protocol
Summary of Contents for CamCor
Page 1: ...CamCor Modbus Protocol Manual Manual No 50284150 Rev 01 ...
Page 4: ...This page is left blank intentionally iv Table of Contents CamCor Modbus Protocol ...
Page 8: ...This page is left blank intentionally 8 Section 2 CamCor Modbus Protocol ...
Page 10: ...This page is left blank intentionally 10 Section 2 CamCor Modbus Protocol ...
Page 22: ...This page is left blank intentionally 22 Section 3 CamCor Modbus Protocol ...