Register
(Decimal)
Register
(Hex)
Description
Default
Data
Type
Data Range
Access
149
0095
High/Low Alarm Source
0
U8
0 = Mass Flow
1 = Volume Flow
2 = Density
3 = Temperature
232 = Net Total 1
231 = Net Total 2
RW
150
0096
Status Input Active Level Setting
0
U8
0 = Closed Active
1 = Open Active
RW
151
0097
Status Output Active Level Setting
152
0098
Slug Flow Detection Delay (sec.)
0
FP
0 – 60
RW
Flow Configuration
Register
(Decimal)
Register
(Hex)
Description
Default
Data
Type
Data Range
Access
97
0061
Flow Direction
0
U8
0 = Positive
1 = Reverse
RW
98
0062
Maximum Density (Slug Flow) (g/ml)
FP
0.000 – 10.000
RW
100
0064
Minimum Density (Slug Flow) (g/ml)
102
0066
Flow Rate Low Cutoff (%)
FP
0.000 – 5.000
RW
Maintenance Configuration
Register
(Decimal)
Register
(Hex)
Description
Default
Data
Type
Data Range
Access
206
00CE
Maintenance Mode
Disabled
U8
RW
207
00CF
Maintenance Mass Flow Rate Unit
U8
RO
208
00D0
Maintenance Mass Flow Rate
FP
-9999999 to 9999999
RW
210
00D2
Maintenance Density
see
, then
see
FP
-9999999 to 9999999
RW
212
00D4
Maintenance Inner Temperature
214
00D6
Maintenance Outer Temperature
216
00D8
Maintenance Volume Flow Rate Unit
U8
RO
217
00D9
Maintenance Volume Flow Rate
FP
-9999999 to 9999999
RW
344
0158
Drive Output Threshold (%)
U32
0.0 to 100.0
RW
Security Configuration
Register
(Decimal)
Register
(Hex)
Description
Default
Data
Type
Data Range
Access
173
00AD
Front Panel Control Lock Setting
0
U8
0 = Unlock
1 = Lock
RW
226
00E2
Write Protect Configuration
0
U8
0 = Disable
1 = Enable
RO
17
CamCor
™
Modbus Protocol
Section 3
Summary of Contents for CamCor
Page 1: ...CamCor Modbus Protocol Manual Manual No 50284150 Rev 01 ...
Page 4: ...This page is left blank intentionally iv Table of Contents CamCor Modbus Protocol ...
Page 8: ...This page is left blank intentionally 8 Section 2 CamCor Modbus Protocol ...
Page 10: ...This page is left blank intentionally 10 Section 2 CamCor Modbus Protocol ...
Page 22: ...This page is left blank intentionally 22 Section 3 CamCor Modbus Protocol ...