FIELD DIMENSIONS

3 s

max. 30 s

The teach-in can be launched either via remote control or via connecting 

the white/red and white/blue wires. 

Launch a teach-in:

• 

after changing the sensor position

• 

when new objects are added to or changed in the detection zone. 

During teach-in, the sensor learns its surroundings and adapts the 

detection field shape to these. Objects in the detection field will be cut out.

IMPORTANT

Test the good functioning of the installation before leaving the premises.

Stay outside of the detection field to avoid disturbances.

WIDTH

field 2 = field 1

HEIGHT

no field

WIDTH

HEIGHT

no field

FIELD 1

FIELD 2

10.0 m

EXAMPLES

for a field width of 6.2 m

for a field height of 4.5 m

Wait for the sensor to learn its environment 

or lock it by remote control.

TEACH-IN

0.1 m    -    25.0 m

10.0 m

10.0 m

10.0 m

To launch a teach-in via input, please contact SENSORIO for more information.

To launch a teach-in via remote control, use the following sequence:

no field

0.1 m    -    25.0 m

0.1 m    -    25.0 m

0.1 m    -    25.0 m

REMOTE CONTROL ADJUSTMENTS (OPTIONAL)

FACTORY VALUES

IMMUNITY FILTER

MIN. OBJECT SIZE

OUTPUT CONFIGURATION

DETECTION FIELD 

REDIRECTION

approximate values

A = active

P = passive

NO = normally open

NC = normally closed

UNCOVERED ZONE

field 1

field 2

field 2

field 1 or 

field 2

off

indoor outdoor

low

outdoor

med

outdoor

high

indoor outdoor

low

outdoor

med

outdoor

high

CURTAIN

    C1   C2     C3    C4

DETECTION CURTAINS

deactivate curtain on both fields

activate curtain only on field 1

activate curtain only on field 2

activate curtain on both fields

EX:

All curtains active on both fields

The distances between the curtains depend on the mounting height and side. When mounted on the left, the distance between the first 

and the last curtain is approximately 10 cm for every meter (mounting height). Example: at 5 m the distance is 50 cm.

C1
C2
C3
C4

C1 + C2 active on field 1 only

C3 + C4 active on field 2 only

C1 active on both fields

C2+C3 active on field 2 only

C4 deactivated

OUTPUT ACTIVATION DELAY 

The outputs are triggered after a constant 

detection time of x ms (ex. value 3= 300 ms).

Increased sensitive (detection of black 

objects, ...)

Increased immunity to rain, snow, fog...

approximate values

Rx= RELAY OUTPUT

off

Summary of Contents for LZR-S25

Page 1: ...1 LZR S25 LASER SCANNER FOR BUILDING AUTOMATION AND SECURITY EN User s Guide for product version 0600 and more ...

Page 2: ...er wavelength 650nm max output CW power 3mW Class 3R according to IEC 60825 1 The visible laser beams are inactive during normal functioning The installer can activate the visible lasers if needed CAUTION Use of controls adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure Do not look into the laser emitter or the visible red laser b...

Page 3: ...connect white red and white blue wires to ground left right MOUNTING SIDE Stay outside of the detection field to avoid disturbances Select the corresponding mounting side The sensor then learns its environment and automatically determines the detection field s Both red LEDs flash slowly and the 3 visible laser beams automatically light up during 30 seconds WITH BACKGROUND WITHOUT BACKGROUND The se...

Page 4: ...ntrol use the following sequence no field 0 1 m 25 0 m 0 1 m 25 0 m 0 1 m 25 0 m REMOTE CONTROL ADJUSTMENTS OPTIONAL FACTORY VALUES IMMUNITY FILTER MIN OBJECT SIZE OUTPUT CONFIGURATION DETECTION FIELD REDIRECTION approximate values A active P passive NO normally open NC normally closed UNCOVERED ZONE field 1 field 2 field 2 field 1 or field 2 off indoor outdoor low outdoor med outdoor high indoor ...

Page 5: ...rol the sensor locks the access to the remote control session The batteries in the remote control are not installed properly or dead The remote control is badly pointed A reflective object is in close proximity to the sensor You have to enter a code or the wrong code was entered The object size is too small The polarity of the power supply is inverted Check cable and connexion Check wiring The red...

Page 6: ... free 35 V DC 24 V AC 80 mA resistive tON 5 ms tOFF 5 ms typ 30 Ω 0 7 V 20 mA 10 µA 2 optocouplers galvanic isolated polarity free 30 V DC over voltage protected Log H 8 V DC Log L 3 V DC 5 ms 1 blue LED power on status 1 orange LED error status 2 bi coloured LEDs detection output status green no detection red detection 125 mm D x 93 mm W x 70 mm H mounting bracket 14 mm PC ASA black or white 45 0...

Reviews: