FIELD DIMENSIONS
3 s
max. 30 s
The teach-in can be launched either via remote control or via connecting
the white/red and white/blue wires.
Launch a teach-in:
•
after changing the sensor position
•
when new objects are added to or changed in the detection zone.
During teach-in, the sensor learns its surroundings and adapts the
detection field shape to these. Objects in the detection field will be cut out.
IMPORTANT
:
Test the good functioning of the installation before leaving the premises.
Stay outside of the detection field to avoid disturbances.
WIDTH
field 2 = field 1
HEIGHT
no field
WIDTH
HEIGHT
no field
FIELD 1
FIELD 2
10.0 m
EXAMPLES
for a field width of 6.2 m
for a field height of 4.5 m
Wait for the sensor to learn its environment
or lock it by remote control.
TEACH-IN
0.1 m - 25.0 m
10.0 m
10.0 m
10.0 m
To launch a teach-in via input, please contact SENSORIO for more information.
To launch a teach-in via remote control, use the following sequence:
no field
0.1 m - 25.0 m
0.1 m - 25.0 m
0.1 m - 25.0 m
REMOTE CONTROL ADJUSTMENTS (OPTIONAL)
FACTORY VALUES
IMMUNITY FILTER
MIN. OBJECT SIZE
OUTPUT CONFIGURATION
DETECTION FIELD
REDIRECTION
approximate values
A = active
P = passive
NO = normally open
NC = normally closed
UNCOVERED ZONE
field 1
field 2
field 2
field 1 or
field 2
off
indoor outdoor
low
outdoor
med
outdoor
high
indoor outdoor
low
outdoor
med
outdoor
high
CURTAIN
C1 C2 C3 C4
DETECTION CURTAINS
deactivate curtain on both fields
activate curtain only on field 1
activate curtain only on field 2
activate curtain on both fields
EX:
All curtains active on both fields
The distances between the curtains depend on the mounting height and side. When mounted on the left, the distance between the first
and the last curtain is approximately 10 cm for every meter (mounting height). Example: at 5 m the distance is 50 cm.
C1
C2
C3
C4
C1 + C2 active on field 1 only
C3 + C4 active on field 2 only
C1 active on both fields
C2+C3 active on field 2 only
C4 deactivated
OUTPUT ACTIVATION DELAY
The outputs are triggered after a constant
detection time of x ms (ex. value 3= 300 ms).
Increased sensitive (detection of black
objects, ...)
Increased immunity to rain, snow, fog...
approximate values
Rx= RELAY OUTPUT
off