TECHNICAL SPECIFICATIONS

Technology:

Detection mode:

Max. detection range:

Remission factor:

Size of target:

Emission characteristics:

IR laser

Red visible laser

Supply voltage:

Power consumption:

Peak current at power-on:

Cable length:

Response time:

Output:

Max. switching voltage:

Max. switching current:

Switching time:

Output resistance:

Voltage drop on output:

Leakage current:

Input:

Response time monitoring input:

LED-signal:

Dimensions:

Material:

Colour:

Mounting angles on bracket:

Rotation angles on bracket:

Tilt angles on bracket:

Protection degree:

Temperature range:

Humidity:

Vibrations:

Pollution on front screens:

Expected lifetime:

Norm conformity:

Max. contact voltage: 

Voltage threshold:

laser scanner, time-of-flight measurement

presence 

(EN 12453 Typ. E)

9.9 m x 

 m

> 2 %

> 300 mm x 200 mm x 700 mm @ 10 m 

(EN 12445 testbody A)

Wavelength 905 nm; max. output pulse power 75 W

wavelength 650 nm; max. output CW power 3 mW

10-35 V DC @ sensor terminal 

< 5 W

1.8 A 

(max. 80 ms @ 35 V)

10 m

typ 20 ms; max. 80 ms

2 electronic relays 

(galvanic isolated - polarity free)

35 V DC / 24 V AC

80 mA 

(resistive)

t =5 ms; t

=5 ms

ON

OFF

typ 30 

Ù

< 0.7 V @ 20 mA

< 10 µA

1 blue LED: power-on status

1 orange LED: error status

2 bi-coloured LEDs: detection/output status 

(green LED: no detection; red LED: detection)

125 mm (D) x 93 mm (W) x 70 mm (H) 

(mounting b 14 mm)

PC/ASA

black

-45 °, 0 °, 45 °

-5 ° to +5 ° 

(lockable)

-3 ° to +3 °

IP65

 

(avoid direct exposure to high pressure cleaning)

-30 °C to +60 °C if powered

-10 °C to +60 °C unpowered

0-95 % non-condensing

< 2 G 

max. 30 %; homogenous

designed for a lifetime of min. 5 years

9.9

2 optocouplers 

(galvanic isolated - polarity free)

30 V DC

 

(over-voltage protected)

Log. H: >8 V DC

Log. L: <3 V DC

< 5 ms

2006/95/EC: LVD; 2004/108/EEC: EMC; 2006/42/EC: MD

2002/95/EC: RoHS; EN 60825-1; EN 60950-1; EN 60529; IEC60825;

EN 61000-6-1: EMC - Commercial Level; EN 61000-6-2: EMC - Industrial level; 

EN 61508 SILCL1 

EN ISO 13849-1:2008 Performance Level «c» CAT 2

Specifications are subject to change without prior notice.

©BEA

42.7269 -V1 / 03.10

 

 

/ Original instructions /

Yves Borlez, Authorized representative

Liege, March 2010

The complete declaration of conformity is available on our website: www.bea.be

BEA hereby declares that the LZR -S600 is in conformity with the basic requirements and the other 
relevant provisions of the standards 2004/108/EEC and 2006/42/EC.

®

Summary of Contents for LZR -S600

Page 1: ...Cable conduit LED signal Visible laser beams Laser sweep reception Laser sweep emission Tilt angle adjustments Main connector Front screens Caution Exposure to laser radiation Factory values See the...

Page 2: ...e device contains IR and visible red laser diodes IR laser CLASS 1 wavelength 905nm max output pulse power 75W Red laser CLASS 3R wavelength 650nm max output CW power 3mW Fasten the sensor firmly to a...

Page 3: ...sition the sensor correctly The grey area indicates the detection range Position the housing on the bracket Turn the sensor until the two triangles are face to face Position the bracket and fasten the...

Page 4: ...sponding mounting side with background Make sure you stay at a distance to avoid disturbances By choosing a value with background the sensor is protected against misuse The sensor memorizes the refere...

Page 5: ...IONS TEACH IN Field height Field width FIELD 2 FIELD 1 3 sec RED RED RED RED Before teach in you have 3 seconds to step out of the detection field 30 sec TEACH IN Wait for the sensor to learn its envi...

Page 6: ...TMENTS Relay configuration 1 Indoor 2 Outdoor LOW 3 Outdoor MEDIUM 4 Outdoor HIGH 0 size filter deactivated 1 5 cm 2 10 cm 3 15 cm 4 20 cm 1 Active NO 2 Passive NC 3 Passive NC 4 Active NO Passive NC...

Page 7: ...aterial in proximity to the sensor Verify the field size Check the position of the sensor Launch a new teach in Check mounting side setting If there is no background set the mounting side to value 3 t...

Page 8: ...typ 20 ms max 80 ms 2 electronic relays galvanic isolated polarity free 35 V DC 24 V AC 80 mA resistive t 5 ms t 5 ms ON OFF typ 30 0 7 V 20 mA 10 A 1 blue LED power on status 1 orange LED error stat...