TROuBLESHOOTING

No blue LED

Only the blue LED 

is on.

The detection LED 

remains green.

The orange LED is 

flashing and the 

detection LEDs are 

red. 

The detection LED 

remains red.

The orange LED 

is on.

The sensor does 

not respond to the 

remote control.

The sensor does 

not unlock.

There is no power.

The test input is not 

connected.

The detection field is too 

small or deactivated.

Someone or something is 

in the detection field.

The field is touching the 

floor, the wall or the door, 

which leads to detection.

No background (reference 

point) is found.

The sensor is masked.

The power supply voltage 

is exceeding the acceptable 

limits.

The sensor exceeds its 

temperature limits.

Internal error

30 minutes after last use 

of the remote control, the 

sensor locks the access to 

the remote control session.

The batteries in the remote 

control are not installed 

properly or dead.

The remote control is badly 

pointed. 

A reflective object is in close 

proximity to the sensor.

You have to enter a code or 

the wrong code was entered. 

The object size is too small.

The polarity of the power 

supply is inverted.

Check cable and connexion.

Check wiring.

The red and blue cable have to be connected 

to the test input or the power supply.

Check the size of the fields.
Launch a teach-in.

Step out of the field and/or remove the any 

object(s) from the field.

Activate the 3 red beams and check if the 

position of the sensor is correct. 

If not, adjust the hex screws.
Verify the field size.
Launch a teach-in.

Check the position of the sensor.

Check the mounting side setting.

If there is no background, set the mounting side 

to value 3 to 5.

Launch a new teach-in.

Verify and clean the front screens 

with a damp cloth.

Check the power supply voltage.

Verify the outside temperature where the sensor 

is installed. Eventually protect the sensor from 

sunlight using a cover.

Wait a few seconds. 

If the LED remains ON, reset the power supply. 

If the LED turns on again, replace the sensor.

Cut and restore power supply. 

The remote control session is accessible again 

during 30 minutes. 

Verify or replace the batteries.

Point the remote control towards the sensor, 

but with a slight angle. The RC should not be 

pointed in a right angle in front of the sensor.

Avoid highly reflective material in proximity to 

the sensor.

Please contact SENSORIO.

Check the polarity of the power supply.

Decrease the min. object size.

Summary of Contents for LZR-W400

Page 1: ...1 LZR W400 Laser scanner for THE SAFETY OF POWER OPERATED WINDOWS EN User s Guide for product version 0700 and more...

Page 2: ...no power power Caution Laser radiation LED flashes quickly LED flashes LED is off Remote control sequence Other use of the device is outside the permitted purpose and can not be guaranteed by the manu...

Page 3: ...red laser beams The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel Only trained and qualified personnel may install and adjust the sensor Avoid extreme vibra...

Page 4: ...4 VERTICAL PROTECTION HORIZONTAL PROTECTION POSSIBLE APPLICATIONS...

Page 5: ...Drill 4 holes as indicated on the mounting template Make a hole for the cable if possible Pass the cable 10 cm though the cable opening If drilling an opening is not possible use the cable conduits o...

Page 6: ...nal a fault in case the orientation of the sensor is changed on purpose or by accident Adjust the lateral position of the detection field Adjust the tilt angle of the detection field with the hex key...

Page 7: ...and adapts the detection field shape to these Objects in the detection field will be cut out IMPORTANT Test the good functioning of the installation before leaving the premises Stay outside of the de...

Page 8: ...NTS OPTIONAL FACTORY VALUES Immunity filter MIN OBJECT SIZE OUTPUT CONFIGURATION approximate values A active P passive UNCOVERED ZONE off indoor outdoor low outdoor med outdoor high indoor outdoor low...

Page 9: ...UES SAVING AN ACCESS CODE DELETING AN ACCESS CODE The access code is recommended for sensors installed close to each other After unlocking the red LED flashes and the sensor can be adjusted by remote...

Page 10: ...he power supply is inverted Check cable and connexion Check wiring The red and blue cable have to be connected to the test input or the power supply Check the size of the fields Launch a teach in Step...

Page 11: ...W CLASS 1 wavelength 650 nm max output CW power 3 mW CLASS 3R 10 35 V DC sensor side 5 W 1 8 A max 80 ms 35 V 10 m typ 20 ms max 80 ms 2 electronic relays galvanic isolated polarity free 35 V DC 24 V...

Page 12: ...the other relevant provisions of the directives 2006 95 EC 2002 95 EC and 2004 108 EC Angleur November 2011 Jean Pierre Valkenberg authorized representative The complete declaration of conformity is a...

Reviews: