A DIVISION OF BEA SA | LIEGE SCIENCE PARK | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM]
T +32 4 361 65 89 | F +32 4 361 28 58 | INFO@SENSORIO.BE | WWW.SENSORIO.BE

BEA hereby declares that the LZR

®

-W400 is in conformity with the basic requirements and the other relevant 

provisions of the directives 2006/95/EC, 2002/95/EC and 2004/108/EC.
Angleur, November 2011 

Jean-Pierre Valkenberg, authorized representative

The complete declaration of conformity is available on our website: www.sensorio.be

EC countries: according to the directive 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE)

 

 | 

O

rig

ina

l i

ns

tr

uc

ti

ons

 |

 

PL

EA

SE

 K

EE

FO

FU

RT

H

ER

 U

SE

D

ES

IG

N

ED

 FOR

 C

O

LO

U

PRI

N

TI

N

G

Summary of Contents for LZR-W400

Page 1: ...1 LZR W400 Laser scanner for THE SAFETY OF POWER OPERATED WINDOWS EN User s Guide for product version 0700 and more...

Page 2: ...no power power Caution Laser radiation LED flashes quickly LED flashes LED is off Remote control sequence Other use of the device is outside the permitted purpose and can not be guaranteed by the manu...

Page 3: ...red laser beams The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel Only trained and qualified personnel may install and adjust the sensor Avoid extreme vibra...

Page 4: ...4 VERTICAL PROTECTION HORIZONTAL PROTECTION POSSIBLE APPLICATIONS...

Page 5: ...Drill 4 holes as indicated on the mounting template Make a hole for the cable if possible Pass the cable 10 cm though the cable opening If drilling an opening is not possible use the cable conduits o...

Page 6: ...nal a fault in case the orientation of the sensor is changed on purpose or by accident Adjust the lateral position of the detection field Adjust the tilt angle of the detection field with the hex key...

Page 7: ...and adapts the detection field shape to these Objects in the detection field will be cut out IMPORTANT Test the good functioning of the installation before leaving the premises Stay outside of the de...

Page 8: ...NTS OPTIONAL FACTORY VALUES Immunity filter MIN OBJECT SIZE OUTPUT CONFIGURATION approximate values A active P passive UNCOVERED ZONE off indoor outdoor low outdoor med outdoor high indoor outdoor low...

Page 9: ...UES SAVING AN ACCESS CODE DELETING AN ACCESS CODE The access code is recommended for sensors installed close to each other After unlocking the red LED flashes and the sensor can be adjusted by remote...

Page 10: ...he power supply is inverted Check cable and connexion Check wiring The red and blue cable have to be connected to the test input or the power supply Check the size of the fields Launch a teach in Step...

Page 11: ...W CLASS 1 wavelength 650 nm max output CW power 3 mW CLASS 3R 10 35 V DC sensor side 5 W 1 8 A max 80 ms 35 V 10 m typ 20 ms max 80 ms 2 electronic relays galvanic isolated polarity free 35 V DC 24 V...

Page 12: ...the other relevant provisions of the directives 2006 95 EC 2002 95 EC and 2004 108 EC Angleur November 2011 Jean Pierre Valkenberg authorized representative The complete declaration of conformity is a...

Reviews: