Locating the features and zone boundaries
Page 92
FiberPatrol FP1150 Product Guide
At splice locations
Tap the cable one fence panel away from the service loop(s) at splice locations.
At sensitivity loops (corners, tension posts, heavy gauge posts)
Tap the cable at the center of the sensitivity loop where it crosses the fence post.
At gate locations
Tap the cable one fence panel away from the isolation loop(s) at gate locations, where the gate will
be assigned as an independent zone. Measure back to the isolation loop (e.g., 3 m) and add 10 m
to place the zone boundary inside the isolation loop. (On the far side of the gate subtract the
distance back to the isolation loop and 10 m to place the zone boundary inside the isolation loop.)
Tap the cable one fence panel away from the gate location if there are no service loops or isolation
loops and the gate will be included as part of another zone.
Figure 99 Tap test location - outdoor splices
Figure 100 Tap test location - at corners or heavy gauge posts
Figure 101 Tap test location - gate (independent zone)
Figure 102 Tap test location - gate (part of zone, no service/isolation loops)
tap cable 1 panel away from service loop
tap cable 1 panel away from service loops
tap cable at center of
sensitivity loop over the post
tap cable 1 panel away from isolation loop
tap cable 1 panel away from isolation loop
isolation
loop
isolation
loop
loop
service
tap cable 1 panel away from gate
tap cable 1 panel away from gate