Locating the features and zone boundaries
FiberPatrol FP1150 Product Guide
Page 93
Tap the cable one fence panel away from the service loop(s) at gate locations, where the gate will
be included as part of a zone.
At bypass locations
Tap the cable two fence panels away from each isolation loop at bypass locations. Record the
location results for both sides of the obstacle. Measure back to the obstacle and add, or subtract,
10 m for each isolation loop. Enter the calculated values as the bypass start and end locations.
At locations of non-linear cable deployment
Tap the cable at the fence posts adjacent to the non-linear deployment.