Processor setup
FP400 Product Guide
Page 69
Network configuration
For FP400 processors that use network alarm data communications, you must setup the network
communication parameters under the Network Cfig tab.
1.
Specify the network Protocol: (Silver Loop or Silver Star).
2.
For the Silver Loop configuration, the network parameters are preset to default values.
For the Silver Star configuration, you must specify the IP Address, the Subnet Mask and the
Gateway IP Address for each processor.
3.
Save and download the configuration changes to the processor.
Note
The Network configuration can be set only through a direct USB
connection between the UCM computer and the processor’s USB port.
Note
There are two selectable configurations for Silver Network based
processors. For EIA-422 and fiber optic cable, select Silver Loop (see
) and for Ethernet communications select Silver
).
Figure 70 UCM Network Configuration example screen
Silver Loop parameters