Installing the sensor cable
Page 40
FlexZone Product Guide
14. Form two 15 cm (6 in.) drip loops and attach the splice enclosure to the fence.
Sensor cable terminations
See
Cable preparation (all connections) on page 37
for steps 1 - 6.
7. For terminations bend and form the section of twisted braided shield on the left side of the
cable into a conductor that is parallel with, and separated from, the center conductor by
5 mm (1/5 in.). Trim the second section of twisted braided shield flush with the black jacket.
8. Trim the twisted braided shield and center conductor to a length of 6 mm (1/4 in.) past the
clear tube.
9. Insert the center conductor into the right side terminal (+) and tighten the screw. Insert the
twisted braided shield into the left hand terminal (-) and tighten the screw. Observe polarity.
10. Secure the sensor cable to the termination CCA using the supplied cable ties. Ensure that the
heads of the cable ties are both on the same side of the CCA and that they are at a 45º angle
from the flat plane of the CCA.
Figure 41: Sensor cable splices steps 12 & 13
Figure 42: Mounting the splice enclosure
Figure 43: Sensor cable terminations steps 7 & 8
dual cable guide bars
dual cable guide bars
center the splice CCA between the dual cable guide bars
locking tabs in slots
15 cm (6 in.)