Modes of operation
6 - 10 • • • Intelli-FLEX II product guide
Function key descriptions
The following table describes the operation of the Configuration module function
keys.
Function key operation in monitor mode
The following section describes the Configuration module key functions. When
the configuration module is in the Monitor mode (
Monitor
LED lit) the keys
function as described below.
Key
Monitor mode
Configure mode
Display
Level
Mode
Select
Toggles to configure mode and displays Zone 1-Cut-
Time Window parameter.
Toggles to monitor mode, and executes
startup routine. Processor does not
reset. Momentarily displays supervisor
L2 alarm status, then Zone 1-Cut display
status.
Display
Select
Sequence to select Zone 1,
Cut, or Climb, Zone 2 Cut, or
Climb
Sequence to select
Zone 1 or Zone 2
Sequence to select Z1-Cut-Time
Window, Z1-Cut-Threshold, etc. through
to Z2-Climb-Threshold, to Z2-Climb-
Time.
Increase
NA
Increases the number
of the Level Register
that is being viewed.
These registers are 0-
12.
Increases the selected parameter value
by 1 unit.
Decrease
NA
Decreases the number
of the Level Register
that is being viewed.
Decreases the selected parameter value
by 1 unit.
Load
NA
NA
Once a parameter value has been
changed, pressing Load will save the
value as the new operational parameter.
Load must be pressed immediately after
Increase or Decrease or the new value
will not be saved.
Clear
Clears supervision alarm
message from display. The
supervision alarm message
must be cleared before other
buttons will function.
Clears display and
display registers to 00.
Sets level mode to
Manual Clear Mode.
NA.
Function
Select
Toggles to Level-Zone 1
mode. Displays level 5. Level
mode always comes up in
Auto Clear.
Toggles to display
mode, Zone 1-Cut
status. (i.e., leaves level
mode.)
After the appropriate Cipher is entered,
Alarm Relay Time, Cut Profile, Peak
Trigger, Ambient Compensation and
Common Mode can be accessed for
Zone 1 and Zone 2.