Installing LM100 luminaires
Page 28
Senstar LM100 Product Guide
3.
Cut back the negative lead 3 cm (1.2 in.) to offset each power cable so the positive lead is
longer than the negative lead.
4.
Pass the power cables through the supplied compression gland, as shown below.
5.
Remove 2 cm (3/4 in.) of the insulation from both conductors on each power cable, and from
both leads of the luminaire.
6.
Tightly twist the 3 wires together to form a single conductor, and trim the single conductor back
to 15 mm (3/8 in.) (i.e., 2 negative conductors from power cables and black lead from
luminaire; 2 positive conductors from power cables and red lead from luminaire).
7.
Insert the single conductor fully into the open-ended connector and verify through the
translucent connector before crimping.
8.
Make the crimp. If the crimp tool you are using does not cover the full length of the internal
crimp ring make a second crimp.
Figure 23: Stripping the leads
Figure 24: Stripping the leads
Figure 25: Forming a single conductor
Figure 26: Preparing the splice
2 cm (3/4 in.) 1 : 1 scale
2 cm (3/4 in.) 1 : 1 scale
15 mm (0.6 in.) 1 : 1 scale
insulation visible
copper wires visible
no visible wires