Installing the LM100 gateway
Senstar LM100 Product Guide
Page 33
Surface mounting
Figure 33: Post-mounting the enclosure (on the fence)
Figure 34: Surface-mounting the enclosure
1. Hold the enclosure against the fence at the specified installation location.
2. Feed the end of the stainless steel clamp through an upper flange slot, around the fence post, and back
through the second slot.
3. Insert the end of the stainless steel clamp into the gear mechanism and tighten the screw.
4. Repeat this with the second clamp on the lower flange at the bottom of the enclosure.
1. Hold the enclosure against the
2. Drill 4 holes in the mounting surface.
3. Using appropriate 6 mm (¼ in.)
mounting surface, and mark the
positions of the 4 mounting holes.
hardware, mount the enclosure.