Introduction
b - 2 • • • MPS-4100 product guide
Features
•
quick connection to network - removable terminal blocks
•
network device address - DIP-switch-selectable
•
network baud rate - DIP-switch-selectable
•
dual redundant communications ports
•
network wiring enters through existing conduit outlet
•
receives power, ground and alarm data through 21-pin header on the Model
MPS-4100 Receiver card
•
fits in Model MPS-4100 Receiver unit enclosure (no modifications required)
•
low power consumption
•
diagnostic LED ON/OFF power switch for reduced power consumption
•
supports dual zone configuration (host/slave) with minimal additional wiring
from the second microwave unit to TB3
•
lightning suppression devices for communication circuits
•
on-board microprocessor
•
conformal coated PCB
•
12 diagnostic/status LEDs:
Software setup
Before installing the Communications Interface Card, configure the MPS-4100
Microwave System in the StarNeT site database as a
PLC-430/IWAVE
Transponder
by following the directions in the
SIMPL Site Creation Guide,
J4DA0202
and the
Control Program Maintenance Guide, J4DA0402
.
System configuration
Before installing the Communications Interface Card, install, align and test the
MPS-4100 microwave system.
LED
Function
LED
Function
LD1
power
Tst 1
self-testing microwave unit 1
Xmit
transmitting data
Tst 2
not used for the MPS-4100
Rec B
receiving data on B side channel
Aud 1
audio output evaluation for zone 1
Rec A
receiving data on A side channel
Aud 2
audio output evaluation for zone 2
Sup 1
supervisory alarm in zone 1
Alm 2
detection alarm in zone 2
Alm 1
detection alarm in zone 1
Sup 2
supervisory alarm in zone 2
Com Card LED functions