Sentera
PHX Unmanned Aircraft Pilot User Guide
www.sentera.com
Page 7
March 19, 2020
844.SENTERA
© 2020 Sentera Inc. All rights reserved.
Tables 4: Temperature Limits
Operational Temperature Limit
Temperature
Minimum
14 F (-10 C)
Maximum
120 F (50 C)
System Storage Temperature Limit
Temperature
Minimum
-10 F (-23 C)
Maximum
120 F (50 C)
Battery Storage Temperature Limit
Temperature
Minimum
40 F (4 C)
Maximum
90 F (32 C)
System Charging Temperature Limit
Temperature
Minimum
40 F (4 C)
Maximum
90 F (32 C)
2.7
Battery Level Limits
The following table describe the various battery limits, as shown in Table 5: Battery Limits.
Table 5: Battery Limits
Battery Level Limit
Volts
Maximum voltage
12.6 volts
Nominal voltage
11.1 volts
Minimum voltage
9.0 volts
Warning:
Battery will be damaged if discharged below 9.0 volts during
operation or if left in storage for a long time. Check battery level every three
months when storing and recharge to 50 percent storage level as needed.
Tip:
Never go below 10 percent battery level during flight. Never go below 6
percent battery level during ground handling.