Step 4: Installation of the EM3000 System
Doc 6001536, Rev C
LOCK WIRING
Wiring the door locks will vary on the type of lock (e.g., Door Strike or Maglock) and "environment"
you wish to employ: fail-safe or fail-secure.
Fail-safe (e.g., Maglock):
If the lock loses power (e.g., from a power failure), the door will unlock.
Fail-secure (e.g., Door Strike):
If the lock loses power (e.g., from a power failure), the door will
remain locked.
Determine which type of environment to use. Is the access control point an area where people need
to exit in case of emergencies? Does the access control area require its doors to lock after a power
failure (e.g., to prevent vandalism)?
COM
COM
N/O
N/O
N/C
N/C
Not Used
Not Used
LOCK
Door Strike
LOCK
Maglock
Diode for Counter EMF
protection (1N4004 or equiv.)
Diode for Counter EMF
protection (1N4004 or equiv.)
MOV (Metal Oxide
Varistor) Siemens
S10K30 or equiv.
MOV (Metal Oxide
Varistor) Siemens
S10K30 or equiv.
Door
Strike
P/S
Battery
Backed
Door
Strike
P/S
Battery Backed
(-)
(-)
(+)
(+)
General Purpose Output
(e.g., Digital Auto-Dialer)
E
xt
ern
ally
W
ire
d
Re
la
y
+12V, 100 mA max.
Normally
Open
Contact
Common
Contact
180 Ohm
300 Ohm
+Input
-Ground
REX
Normally
Closed
Contact
Common
Contact
180 Ohm
300 Ohm
+Input
-Ground
DOOR SENSE
Lock
(see detail)
Open
Collector
Note: 100 mA
Open Collector ONLY
1536F11
COM
NORM
OPEN
NORM
CLOSED
REX
REX
DOOR STAT
DOOR STAT
+LOC
ALM
-LOC
ALM
COM
NORM
OPEN
NORM
CLOSED
REX
REX
DOOR STAT
DOOR STAT
+LOC
ALM
-LOC
ALM
Figure 15: Maglock and Door Strike Wiring