The exposure device contained in the transport package meets the requirements for a Type A transport
packages under IAEA TS-R-1(2009), USNRC 10CFR71, USDOT 49CFR173 and was designed to meet the
applicable specifications of ISO 3999:2004(E) for Category X exposure devices.
Inspection requirements:
A daily inspection of the device for obvious defects is required. Complete annual servicing and /or collimator
replacement can only be performed at Sentinel
TM
-QSA Global, Inc. one of the authorized service centers,
typically during source reloading.
Operating temperature range:
-40°F to 300°F (-40°C to 149°C)
Sentinel
TM
Model 989 actuators for radiographic exposures:
The Model 989 exposure device is compatible for use with Sentinel
TM
manufactured crank-out remote
controls or air pressure actuators (Part number ELE 027). For designed radiological safety, the only crank-out
remote controls and air pressure actuators that can be used with the exposure device must be authorized by
Sentinel
TM
- QSA Global, Inc.
When used with the ELE027, air pressure actuation for exposures is controlled using either the Model 86550
or JB193-000 air controller pump box units. When air actuated, the air hose length used between the pump box
and the Model 989 can vary from 15 to 50 ft. (4.6 to 15.2 m).