ECO: 102-0461-01
S-4014
Rev B
18
S-4007 Blower flat plug (optional)
•
Remove blower plug from cartridge package and discard poly bag.
•
Remove blower plug installation tool from cartridge package and discard poly
bag.
•
Verify that the blower plug and blower inlet connection thread are not damaged.
•
Screw the plug directly into bottom blower inlet. (See figure 2)
•
Using blower flat plug installation and removal tool, align and insert tool pins
into blower plug. (See figure 3)
•
Using a 1/2” box end wrench, or similar tool, secure blower plug ensuring a
tight seal against inlet gasket. (See figure 4)
Figure 1
Figure 2
Figure 3
Figure 4
10. Check the airflow with the Flow Meter
• Ensure that the cartridges are installed on the blower. The blower can be installed
on the waist belt.
• Switch the blower
ON
. A short beep should sound.
• Place the flow meter in the blower’s hood connector, applying light pressure to
allow a seal between the flow meter and the blower. Keep the flow meter vertical.
• The position of the upper (flat surface) black cone in the flow meter should be
above the indication line. If any part of the upper (flat surface) of the black cone is
below the line on the flow meter,
DO NOT
USE and check for:
o
Blower malfunction.
o
Clogged or damaged cartridges.
o
Low battery charge or battery malfunction.