ECO: 102-0461-01
S-4014
Rev B
26
REMOVING THE PAPR SYSTEM
Remove the blower and hood in a safe hazard-free area.
•
Doff the hood.
•
Remove the belt and blower from your waist, (blower should be working at this
stage).
•
Turn the blower
OFF
.
INSPECTION
After each use, inspect the hood to identify signs of damage or wear that may affect
performance of the respirator and reduce the degree of protection provided. The
Troubleshooting Section, in this manual, contains a troubleshooting guide to help you
identify the proper action to take for specific problems that may be detected.
Hood
Check that there are no tears or punctures in the Sentinel XL
™
Clear Hood. Look
closely at the stitching. There should be no tears that could permit contaminated air to
enter the hood.
Visor
Look for scratches or other visual distortions that make it difficult to see through visor.
Breathing Hose
Carefully examine the entire breathing hose. Look for tears, holes or cracks. Bend the
hose to verify that it is flexible.
PAPR Blower Unit
Remove the cartridges and assure that the rubber gaskets are in place in the blower.
Examine the blower housing for cracks. Replace if cracked or damaged.
Examine the outside of the battery pack for cracks. Replace if damaged.
Cartridges
Examine cartridges for mechanical damage and deformities. Replace if damaged.
Blower Plug
Examine the plug in the blower inlet, and insure a tight seal against the internal gasket.
Re-tighten if necessary.