Instructions for installation and use
p. 26/28
10. Technical data
The dimensions of the various power rating versions can be found in
Fig. 6
and
Fig. 7
on page
27
.
Item
number
Power
rating
[kW]
Cabin
volume
[m
3
]
Minimum size of
ventilation opening
[mm]
Weight
without
stones
[kg]
CP-RB-090
9.0
9 – 14
350 x 50
34
CP-RB-105
10.5
10 – 15
350 x 60
34
CP-RB-120
12.0
14 – 18
350 x 70
40
CP-RB-150
15.0
18 – 25
350 x 90
40
Item
number
Stone weight
[kg]
Fuse [A]
Supply voltage
CP-RB-090
approx. 25
3 x 16
400 V AC 3N~ 50/60 Hz
230 V AC 1N~ 50/60 Hz
CP-RB-105
approx. 25
3 x 16
400 V AC 3N~ 50/60 Hz
230 V AC 1N~ 50/60 Hz
CP-RB-120
approx. 35
3 x 16 / 3 x 10
400 V AC 3N~ 50/60 Hz
CP-RB-150
approx. 35
3 x 16 / 3 x 10
400 V AC 3N~ 50/60 Hz
Item
number
Heating rods
CP-RB-090
6 x SCA150 (1-028-518)
CP-RB-105
3 x SCA150 (1-028-518) / 3 x SCA200 (1-028-503)
CP-RB-120
6 x SCA150 (1-028-518) / 3 x CPRM115 (1-043-621)
CP-RB-150
6 x SCA150 (1-028-518) / 3 x SCA200 (1-028-503)