Return Merchandise Authorization 

If you have a unit that is not functioning properly and is in need of technical assistance or repair: 

Submit a request for support by phone at the above number, or via the web at 

www.servertech.com/forms/techrequest.htm

Be ready to provide:  

Company Name 

 

Contact Name, Phone Number, and Email address 

 

Model or Part Number (from the label on the equipment) 

 

Server Technology Serial Number 

 

Version of code (type ‘vers’ at the Sentry: prompt) 

 

Description of problem 

1.  Technical Support will work to diagnose/resolve the problem remotely, if possible.  If the problem 

cannot be resolved, Technical Support will then issue an RMA# for the return/repair of the 
equipment in question.  RMA#’s are valid for 30 days only from the issue date. 

2.  Shipping charges for the return of the equipment to Server Technology shall be the responsibility 

of the customer.  For warranty repairs, Server Technology shall assume return shipping charges but 
for non-warranty repairs, the shipping charges shall be billed. 

3.  The RMA# shall be placed conspicuously on all shipping documentation, associated 

correspondence, and the shipping container. 

4.  Equipment must be returned in proper/original packaging to protect the equipment in transit.  The 

customer shall be financially responsible for any damage/destruction of the equipment due to 
improper packaging. 

5.  Equipment shall typically be turned around within 48-72 hours of receipt at Server Technology.  

Equipment under warranty shall be repaired at no cost.  Equipment NOT under warranty shall be 
repaired at the standard labor rate plus parts.  Upon diagnosis of the equipment, the customer shall 
be notified of estimated charges prior to repair. 

6.  For non-warranty repairs, return of the equipment will be expedited with the inclusion of a 

Purchase Order or credit card number for incurred charges.

Sentry Power Tower Power Distribution Unit 

Appendices 

 

21

 

Installation and Operations Manual 

 

Warranty, Product Registration and Support 

 

Summary of Contents for PTPD-H0

Page 1: ...Sentry AC Power Distribution Unit PTPD V0 PTPD H0 PTPD VE PTPD HE Installation and Operations Manual...

Page 2: ...alysis systems peritoneal dialysis systems neonatal ventilator incubators ventilators for adults or infants anesthesia ventilators infusion pumps and any other devices designated as critical by the U...

Page 3: ...Mounting 6 Connecting to the Power Source 6 Connecting Devices to the PTPD 7 Connecting to the PTPD PTPD x0 models only 7 CHAPTER 3 OPERATIONS PTPD X0 MODELS ONLY 9 Interface 10 Displaying the Contro...

Page 4: ......

Page 5: ...Chapter 1 Introduction FEATURES AND BENEFITS 2 Power Distribution 2 Load Measurement 2 Over Threshold Notification 2 Technical Support 2 QUICK START GUIDE 2...

Page 6: ...PD xE models Over Threshold Notification Sentry Power Distribution Units features two standard over threshold alarms an audible alarm for the local technician and a contact closure alarm circuit which...

Page 7: ...ITEMS 4 EQUIPMENT OVERVIEW 4 SAFETY PRECAUTIONS 5 VERIFY INPUT VOLTAGE SELECTION PTPD VE18 MODELS ONLY 5 MOUNTING 6 Horizontal Rack PTPD 6 Vertical PTPD 6 CONNECTING TO THE POWER SOURCE 6 CONNECTING D...

Page 8: ...ough A4 B1 through B4 C1 through C4 and D1through D4 The power inlet of the PTPD connects the PTPD to the electrical power source See Appendix C Technical Specifications for more information Ports Inp...

Page 9: ...wer supply cord shall be installed near the equipment and shall be easily accessible La prise sur le cordon d alimentation sera install e pr s de l quipement et sera facilement disponible Der Stecker...

Page 10: ...es Representative for information regarding custom bracket design and fabrication services if you are unable to find a suitable manner for utilizing the included mounting brackets Connecting to the Po...

Page 11: ...esigned for use with Server Technology s IEC 60320 C13 to IEC 60320 C14 cable CAB 1302 The retention clip may not properly fit 3rd party cables Always disconnect the power supply cord before opening t...

Page 12: ......

Page 13: ...reen 10 USING THE CONTROL SCREEN 10 Location field 10 To specify a location 10 Input Current field 10 Threshold field 10 To adjust the overload threshold 10 Alarm Status field 11 Clearing an Over Thre...

Page 14: ...ocation field T Pressing T allows editing of the overload threshold Enter Displays or refreshes the Control Screen The following sections describe each Control Screen field Location field The editable...

Page 15: ...rrent returns to 1 8 ampere below the overload threshold To clear an alarm from the Control Screen Type c To clear an alarm using the reset button On the front of the PTPD locate the recessed reset bu...

Page 16: ......

Page 17: ...TIONAL VOLTAGE 15 APPENDIX C TECHNICAL SPECIFICATIONS 16 Standard Models 16 Ratings 17 Fuses 17 Data Connection PTPD x0 models only 18 RJ45 to DB9F serial port adapter 18 IDC10 alarm port 19 APPENDIX...

Page 18: ...eset button directly below the Input Current LED You will need a non conductive non metallic tool that fits inside the recess Insert the tool in the recess then depress and hold the reset button for a...

Page 19: ...crews from access plate on the back of the Sentry Power Distribution Unit 2 2 Remove the access plate 3 Verify the proper setting on the voltage selector switch Correct as necessary 115V for 100 120V...

Page 20: ...red NEMA 5 15P 15A 125V straight 18 IEC 60320 C13 PTPD VE18 0 04 100 240V 50 60Hz Hardwired NEMA L5 20P 20A 125V locking 18 IEC 60320 C13 PTPD VE18 0 05 100 240V 50 60Hz Hardwired NEMA L5 30P 30A 125V...

Page 21: ...D4 or 9 10 11 12 13 14 15 16 5 1 2 3 4 5 6 OR 7 8 9 10 11 12 OR 13 14 15 16 17 18 Les configurations suivantes NE SONT PAS disponible Unit s de 100 120V avec indice de courant d entr e de 16A Unit s d...

Page 22: ...an RJ45 RS 232c serial port This connector may be used for direct local access or from other serial devices such as a terminal server An RJ45 crossover cable is provided for connection to an RJ45 DTE...

Page 23: ...The relay switches to close the circuit in response to an over threshold alarm Normally Closed The relay switches to open the circuit in response to an over threshold alarm 2 Relay specifications Manu...

Page 24: ...strict compliance with Server Technology s operation and installation manual c has become defective or inoperative due to its integration or assembly with any equipment or products not supplied by Ser...

Page 25: ...irs Server Technology shall assume return shipping charges but for non warranty repairs the shipping charges shall be billed 3 The RMA shall be placed conspicuously on all shipping documentation assoc...

Page 26: ...a 89521 775 284 2000 Fax 775 284 2065 E mail sales servertech com World Wide Web www servertech com Sentry and Sentry Power Distribution Unit are trademarks of Server Technology Inc 301 0121 1 Rev C 0...

Reviews: