background image

E

N

G
LI
S

H

afe

:

Clo

se

 th

e d

oo

r a

nd

 re

tu

rn

 th

e h

an

dle

 to

 th

e h

ori

zo

nta

l p

osi

tio

n.

5

Advanced LCD electronic lock

For safes with an 

electronic lock and a key lock

For added security, some models have dual
locking system (electronic lock plus key lock).
You

MUST

use both the electronic code and

the key to open the safe.

To open your safe for the first time:

Install 4 AA batteries. (See instructions under
“Electronic lock”.)
Turn the key to the right so that cylinder pops out.
Enter the electronic lock code printed on the front
cover, then press the Prog/Enter key. When the green
PROCEED light comes on, you have four seconds to
turn the handle down to open.

Using the keypad

Caution!

Liquids can damage the keypad!

Caution!

Pen points or other sharp objects can puncture 

the keypad membrane!

Only a light touch is needed. Press any button, the keypad
lights up and a single beep will indicate that the keypad “felt”
your touch. The lock allows 5 seconds for each key press.
After 5 seconds, 3 beeps will sound and a red light will blink.
Start over if this occurs.

Access codes

There are three ways to unlock and access the safe. Use
one of the following, then press the 

Prog/Enter

key:

1. Enter the preset 5-digit electronic lock  combination.

This code cannot be deleted and can always be used to
open the safe - keep it secure!

2. A 4–8 digit Manager Code can be programmed and

changed as needed.

3. For temporary access to the safe, you can program 

up to six 4–8 digit User Codes that can be erased 
or changed. 

NOTE: All zeros is an invalid code.

Open first – test combination

with door open!

Test your new LCD electronic lock codes several times with
the door open to be sure you have entered them correctly.

NOTE: To return to the beginning when inputting 

a programmed Manager, User or Factory Code,
press 

CLEAR

. You may then re-enter the Code.

NOTE: To turn the beeper on or off, press the 

0

key

and then the 

Prog/Enter

key. (

0

Prog/Enter

)

Programming the Manager Code

NOTE: One (1) Manager Code is allowed.

To add:

1. Press the Prog/Enter key, then enter the 5-digit 

electronic lock combination and then press the 
Prog/Enter key.

2. An empty lit box means no Manager Code is programmed. 

A boxed lighted

*

means a Manager Code is programmed.

3. Enter a 4 to 8 digit code and press the Prog/Enter key to

finish programming the code into the unit.

To delete:

1. Press the Prog/Enter key, then enter the 5-digit 

electronic lock combination and then press the 
Prog/Enter key.

2. A boxed lighted 

*

icon indicates there is a code 

programmed and can be deleted.

3. Press 0, 0, 0, 0, then the Prog/Enter key to delete the

Manager Code.  (0, 0, 0, 0, Prog/Enter )

NOTE: To return to the beginning when 

programming a Manager or User Code, wait 
5 seconds and the lock will time-out. You may
then start over.

Programming User Codes

NOTE: Six (6) user codes are allowed.

To add:

1. Press the 

Prog/Enter

key 2 times, enter the Manager Code

and then press the Prog/Enter key.

2. Use the << or >> to scroll between the lighted boxes. An

empty box means it is available for a code entry; a boxed
lighted 

*

means it is being used.

3. Enter a 4 to 8 digit code in the selected position and press

the Prog/Enter key to finish programming the code into the
unit.

To delete:

1. Press the 

Prog/Enter

key 2 times, enter the Manager Code

and then press the 

Prog/Enter

key.

2. Use the << or >> to scroll to the boxed lighted 

*

icon 

to be removed. 

3. Press 

0, 0, 0, 0

, then the 

Prog/Enter

key to delete the 

selected user.  

(

0, 0, 0, 0

,

Prog/Enter)

NOTE: To return to the beginning when 

programming a Manager or User Code, wait 
5 seconds and the lock will time-out. You may
then start over.

To unlock safe:

E

nter the preset 5-digit electronic lock combination, a

Manager Code or a User Code and press the 

Prog/Enter

key. An

asterisk will light each time a digit is entered. When the

unlocked padlock icon

appears you have 4 seconds to turn the

handle and open the safe.  

To lock safe:

Close the door and return the handle to the horizontal 
position.

Keep your Manager 

and User Codes secure

Maintain a record of your Manager and User Codes and store
them in a secure location, other than in the safe.

Record your Manager 

and User Codes here

Manager Code:   ____   ____   ____   ____   ____

User Code:         ____   ____   ____   ____   ____

Battery replacement

The battery icon will light when the batteries need to be
replaced. No codes are erased when old batteries are
removed for replacement. See “

Battery installation

” in 

the “

Electronic lock

” section for installation instructions.

NOTE: If your safe does not appear to be working, 

please check batteries before calling Sentry
Customer Service.

Icon identification

ERR

(Error) 

indicates one  of the following:

1. You have pressed 

Program

key out of sequence.

2. You have entered an invalid code.
3. You have let 5 seconds elapse between key presses.

PRG (

Program

)

Lights after pressing the 

Program

key and stays lit while pro-

gramming a Manager or User Code.

*

(

Asterisk

) indicates one  of the following:

1. A number key has been pressed.
2. In 

Program

mode, it signals a programmed code location.

Boxes

Light during programming and indicate code locations. 

• An empty lit box means no code is programmed. 
• A boxed lighted 

*

means a code is programmed.

Padlock

Lights after three consecutive invalid codes are input and
stays lit during the 2-minute delay mode.

Unlocked Lock

Lights when a valid code is entered. Indicates that the safe is
unlocked and the door can be opened.

Battery

Lights when batteries are low indicating that the batteries
need to be replaced soon.

Horn

Lights when the beeper is on.

Delay mode

The lock automatically enters a two-minute delay mode after
an invalid code has been entered three consecutive times. In
this mode, the lock can not be activated and the 

PADLOCKED

icon lights.

Summary of Contents for FIRE SAFE

Page 1: ...Informationen zum Öffnen und Schließen des Safes finden Sie auf den Seiten 24 28 Auf der Rückseite der Bedienungsanleitung befinden sich Angaben zum Modell und zur Kombination Manual Bagi Pemilik lemari besi merek FIRE SAFE Untuk informasi lebih lanjut tentang menggunakan kunci lemari besi Anda harap membaca halaman 29 33 Lihat sampul belakang untuk membaca informasi tentang Model dan lainnya Manu...

Page 2: ... card AUSTRALIA Replace Paragraph 1 with the following Except for damages caused by gross negligence or willful misconduct and in any event to the extent allowed by the applicable laws and rules on manufacturer s liability for defective products Sentry s responsibility and the buyer s exclusive remedy under this Limited Warranty are limited to the repair or replacement of the defective part s of t...

Page 3: ...r hinge out side WARNING DO NOTstore delicate items directlyin yoursafe SentrySafe products which offer fire protection have a patented insulation that has a high moisture content In addition the SentrySafe advanced safes close airtight to offer water resistance which may also cause moisture to accumulate inside your safe The desiccant packet included in your safe during shipment should be left in...

Page 4: ... Enter the preset 5 digit electronic lock combination This code cannot be deleted and can always be used to open the safe keep it secure 2 A 5 digit User Code of your choice can be pro grammed and changed as needed 3 For temporary access to the safe you can program a 5 digit User PIN that can be erased or changed NOTE All zeros is an invalid code Programminga5 digitUserCode 1 Press the Program key...

Page 5: ...er Programming UserCodes NOTE Six 6 user codes are allowed To add 1 Press the Prog Enter key 2 times enter the Manager Code and then press the Prog Enter key 2 Use the or to scroll between the lighted boxes An empty box means it is available for a code entry a boxed lighted means it is being used 3 Enter a 4 to 8 digit code in the selected position and press the Prog Enter key to finish programmin...

Reviews: