background image

As per 06/2016

6

  

 

 

Risk of spreading fire

 

 

Can cause fires to spread. Do not direct the airflow (intake/exhaust

 

 

side) at potential sources of fire.

Hot surfaces

  

 

 

High temperatures at motor housing

 

 

Risk of burns

 

 

Provide adequate protection against accidental contact.

Transport, Storage, Cleaning and Disposal

Transport and  

Only transport the product in its original packaging and secure during

Storage

 

transport. The humidity levels and the temperature stipulated in the

 

 

technical data should not be exceeded during transport. 

 

 

Store the product in a dry and clean environment that is adequately 

  

protected.

 

 

    

Cleaning 

Product damaged during cleaning

 

 

Before commencing the cleaning, ensure that the product is switched off.

 

 

Clean the product carefully with a damp cloth or brush without 

 

 

applying pressure to the rotor. Do not use cleaning agents that contain  

 

 

acid, caustic or solvent additives.

Disposal 

Observe the valid requirements and regulations pertaining to disposal

 

 

that are applicable in your country.

CAUTION

!

CAUTION

!

Summary of Contents for MEB50E-05

Page 1: ...OPERATING MANUAL DIRECT CURRENT DC Fans GmbH SEPA EUROPE GmbH Hartheimer Stra e 6 D 79427 ESCHBACH...

Page 2: ...Electromagnetic radiation 4 Mechanical movement 5 Hot surfaces 6 Transport Storage Cleaning and Disposal 6 2 Intended use 7 Intended use comprises 7 Improper use 7 3 Technical data 8 4 Connection and...

Page 3: ...risk of serious and mortal injuries if the safety instructions are not observed Observe the safety instructions at all times Warning The dangerous situation can occur and can result in serious and mo...

Page 4: ...an occur by reaching into the product during operation Do not operate the product without a protection against accidental contact protection guard so that parts that are rotating or energized cannot b...

Page 5: ...er Before starting the product ensure that it is fixed securely and the protection guards are in place Parts transported by the airflow The product can transport small parts in the airflow and catapul...

Page 6: ...The humidity levels and the temperature stipulated in the technical data should not be exceeded during transport Store the product in a dry and clean environment that is adequately protected Cleaning...

Page 7: ...t with materials that can damage product components e g acids caustic solutions solvents Exposure to radiation that can damage the product components e g strong UV rays or heat radiation Operating the...

Page 8: ...d by a qualified electrician and after the mechanical installation Always comply with the electrical installation regulations Observe the connection regulations that are valid in your country e g fuse...

Page 9: ...product before putting the product into operation Check that the data on the nameplate corresponds with the pin connection data Only use cables that are designed for the current stipulated on the nam...

Page 10: ...foreign objects Remove them if necessary Apply the nominal voltage to supply the product Start the product after changing the input signal Switch off product Switch off the product via the control in...

Page 11: ...rupted Exchange product Ambient temperature too Reduce ambient temperature high if possible Impeller runs Unbalance of rotating Clean product If still running untrue untrue parts after cleaning exchan...

Page 12: ...e Assembly instructions according to Art 18 1 Installation instructions according to Art 18 1 Operating Manual according to Art 18 3 Maintenance Manual according to Art 18 1 Usage restriction notice f...