As per 06/2016
7
2. Intended use
The product is designed exclusively as a built-in device for conveying air according to the
relevant technical data. Every use other than the intended use is regarded as misuse of the
product.
The customer’s equipment must comply with the applicable mechanical, thermal and ser-
vice life requirements
Intended use comprises:
• Operating the product with all protective equipment
• Not putting the product into operation before it has been installed in the customer’s
application
• Observing the Operating Manual
Improper use
Using the product for the following purposes is prohibited and can be dangerous:
• Conveyance of air that contains abrasive particles
• Conveyance of air that has a highly corrosive effect
• Conveyance of air that has a high dust load, e.g. suctioning off saw dust
• Conveyance of inflammable gases/particles
• Contact with materials that can damage product components, e.g. acids, caustic
solutions, solvents
• Exposure to radiation that can damage the product components, e.g. strong UV rays
or heat radiation.
• Operating the product close to inflammable materials or components
• Operating the product in an explosive atmosphere
• Use of the product as a safety component or for performing safety-relevant functions
• Operating in devices with life-sustaining or life-saving function
• Operating in systems that demand higher product requirements than those defined in
the data sheet.
• Operating with fully or partially dismantled or manipulated protective equipment
• Operating the product under conditions other than those mentioned in the technical data
• Furthermore, all areas of application not mentioned under intended use
An in situ assessment must be carried out of the heating (proper and improper operation)
and the protection against contact, foreign bodies and humidity as well as usage at
heights >2000 m.
Should you have any specific questions, please contact
SEPA
EUROPE GmbH
.
GmbH