background image

As per 06/2016

7

2. Intended use

The product is designed exclusively as a built-in device for conveying air according to the 
relevant technical data. Every use other than the intended use is regarded as misuse of the 
product. 

The customer’s equipment must comply with the applicable mechanical, thermal and ser-
vice life requirements

Intended use comprises:

•  Operating the product with all protective equipment
•  Not putting the product into operation before it has been installed in the customer’s

 application

•  Observing the Operating Manual

Improper use

Using the product for the following purposes is prohibited and can be dangerous:

•  Conveyance of air that contains abrasive particles
•  Conveyance of air that has a highly corrosive effect
•  Conveyance of air that has a high dust load, e.g. suctioning off saw dust
•  Conveyance of inflammable gases/particles
•  Contact with materials that can damage product components, e.g. acids, caustic 

 

solutions, solvents

•  Exposure to radiation that can damage the product components, e.g. strong UV rays 

 

or heat radiation.

•  Operating the product close to inflammable materials or components
•  Operating the product in an explosive atmosphere 
•  Use of the product as a safety component or for performing safety-relevant functions
•  Operating in devices with life-sustaining or life-saving function
•  Operating in systems that demand higher product requirements than those defined in 

 

the data sheet.

•  Operating with fully or partially dismantled or manipulated protective equipment
•  Operating the product under conditions other than those mentioned in the technical data
•  Furthermore, all areas of application not mentioned under intended use

An in situ assessment must be carried out of the heating (proper and improper operation) 
and the protection against contact, foreign bodies and humidity as well as usage at 
heights >2000 m.

Should you have any specific questions, please contact 

SEPA

 EUROPE GmbH

.

GmbH

Summary of Contents for MEB50E-05

Page 1: ...OPERATING MANUAL DIRECT CURRENT DC Fans GmbH SEPA EUROPE GmbH Hartheimer Stra e 6 D 79427 ESCHBACH...

Page 2: ...Electromagnetic radiation 4 Mechanical movement 5 Hot surfaces 6 Transport Storage Cleaning and Disposal 6 2 Intended use 7 Intended use comprises 7 Improper use 7 3 Technical data 8 4 Connection and...

Page 3: ...risk of serious and mortal injuries if the safety instructions are not observed Observe the safety instructions at all times Warning The dangerous situation can occur and can result in serious and mo...

Page 4: ...an occur by reaching into the product during operation Do not operate the product without a protection against accidental contact protection guard so that parts that are rotating or energized cannot b...

Page 5: ...er Before starting the product ensure that it is fixed securely and the protection guards are in place Parts transported by the airflow The product can transport small parts in the airflow and catapul...

Page 6: ...The humidity levels and the temperature stipulated in the technical data should not be exceeded during transport Store the product in a dry and clean environment that is adequately protected Cleaning...

Page 7: ...t with materials that can damage product components e g acids caustic solutions solvents Exposure to radiation that can damage the product components e g strong UV rays or heat radiation Operating the...

Page 8: ...d by a qualified electrician and after the mechanical installation Always comply with the electrical installation regulations Observe the connection regulations that are valid in your country e g fuse...

Page 9: ...product before putting the product into operation Check that the data on the nameplate corresponds with the pin connection data Only use cables that are designed for the current stipulated on the nam...

Page 10: ...foreign objects Remove them if necessary Apply the nominal voltage to supply the product Start the product after changing the input signal Switch off product Switch off the product via the control in...

Page 11: ...rupted Exchange product Ambient temperature too Reduce ambient temperature high if possible Impeller runs Unbalance of rotating Clean product If still running untrue untrue parts after cleaning exchan...

Page 12: ...e Assembly instructions according to Art 18 1 Installation instructions according to Art 18 1 Operating Manual according to Art 18 3 Maintenance Manual according to Art 18 1 Usage restriction notice f...