background image

As per 06/2016

9

 

 

 

Electromagnetic compatibility (EMC) may affect system integration of the

 

 

product due to interaction. Ensure the electromagnetic compatibility of the

 

 

complete system.

Voltage control (if existing)

Speed control via the supply voltage is only permitted within the stipulated supply voltage 
range. A speed control via PWM of the supply voltage is not permitted.

Requirements

Ensure that the voltage supply corresponds with the voltage of the product before putting 
the product into operation.

Check that the data on the nameplate corresponds with the pin connection data.

Only use cables that are designed for the current stipulated on the nameplate and for the 
corresponding ambient conditions. Ensure that the electrical connection has adequate 
mechanical protection.

Check connections

Cut off the power at all phases and ensure that it cannot be switched on again.

Check that the connector contacts are correctly connected to the connection cable and 
the panel-mounted connectors are correctly connected to one another.

  

 

 

DC fans 

120VAC are products of Protection Class III!

GmbH

NOTICE

NOTICE

Summary of Contents for MEB50E-05

Page 1: ...OPERATING MANUAL DIRECT CURRENT DC Fans GmbH SEPA EUROPE GmbH Hartheimer Stra e 6 D 79427 ESCHBACH...

Page 2: ...Electromagnetic radiation 4 Mechanical movement 5 Hot surfaces 6 Transport Storage Cleaning and Disposal 6 2 Intended use 7 Intended use comprises 7 Improper use 7 3 Technical data 8 4 Connection and...

Page 3: ...risk of serious and mortal injuries if the safety instructions are not observed Observe the safety instructions at all times Warning The dangerous situation can occur and can result in serious and mo...

Page 4: ...an occur by reaching into the product during operation Do not operate the product without a protection against accidental contact protection guard so that parts that are rotating or energized cannot b...

Page 5: ...er Before starting the product ensure that it is fixed securely and the protection guards are in place Parts transported by the airflow The product can transport small parts in the airflow and catapul...

Page 6: ...The humidity levels and the temperature stipulated in the technical data should not be exceeded during transport Store the product in a dry and clean environment that is adequately protected Cleaning...

Page 7: ...t with materials that can damage product components e g acids caustic solutions solvents Exposure to radiation that can damage the product components e g strong UV rays or heat radiation Operating the...

Page 8: ...d by a qualified electrician and after the mechanical installation Always comply with the electrical installation regulations Observe the connection regulations that are valid in your country e g fuse...

Page 9: ...product before putting the product into operation Check that the data on the nameplate corresponds with the pin connection data Only use cables that are designed for the current stipulated on the nam...

Page 10: ...foreign objects Remove them if necessary Apply the nominal voltage to supply the product Start the product after changing the input signal Switch off product Switch off the product via the control in...

Page 11: ...rupted Exchange product Ambient temperature too Reduce ambient temperature high if possible Impeller runs Unbalance of rotating Clean product If still running untrue untrue parts after cleaning exchan...

Page 12: ...e Assembly instructions according to Art 18 1 Installation instructions according to Art 18 1 Operating Manual according to Art 18 3 Maintenance Manual according to Art 18 1 Usage restriction notice f...