OPERATION
Input 1 (digital)
■
Pulse
Configuration of the input as pulse input
Contact
NO / NC contact - Configuration of the contact type (NO or NC contact).
Input 2
■
External Stop
Function for stopping the pump externally.
NOTE
The External Stop symbol is shown in the display if the pump is stopped using Exter-
nal Stop.
Contact
NO / NC contact - Configuration of the contact type (NO or NC contact).
ATTENTION
To avoid damaging the pump, perform parametrisation of the inputs and outputs
before connecting the control cable.
Outputs 1 and 2 (digital)
■
Ready to run
Signal for operational readiness of the pump.
■
Stroke signal
Message when a stroke is executed.
Contact
NO / NC contact - Configuration of the contact type (NO or NC contact).
Input 1
Pulse input
Input 2
External stop
Output 1
Output 2
Ready to run
Stroke signal