Systèmes de dosage – construction verticale
CVD 1 (s) / CVD 2
Notice d’utilisation
TA450-11 / fr/en / 01.2017 / PM
www.sera-web.com
Sous réserve de modifications techniques !
Subject to technical modifications!
39
7.1.6 CVD1 – option
splash guard (Pos. 500)
A detachable splash guard can be attached to the mounting
plate to protect the operating personnel from chemical splash-
es which may occur due to damage on the system.
Fig.14 Option splash guard
7.1.7 CVD1 – Option
terminal box (Pos. 600),
socket (Pos. 650 / 660) and
main switch (Pos. 610)
The system can be fitted with a terminal box or a socket or a
main switch as transition points for power connections or a
signal exchange.
Fig.15 Option terminal box, socket and main switch
7.1.8
CVD1 – option leakage sensor
(Pos. 700 / 710)
A magnetic float switch (pos. 700) or a leakage sensor (pos.
710) detects leakages at the system. This optional device can
be integrated in the collecting basin.
Fig.16 Option leakage sensor
CAUTION !
The magnetic float switch (Pos. 700) is not approved
according to WHG!
700
710