background image

9

sera refill packages, additional modules and spare
parts:

sera siporax

®

mini for sera fil 60/120 Item no. 06853

sera super carbon activated filter carbon for sera fil
60/120 
Item no. 06854
Filter foam for sera fil 60/120 Item no. 06855
Front filter cartridge (empty) for sera fil 60/120 Item
no. 06852
Filter cartridge (empty) for sera fil 60/120 Item no.
06850
Impeller for sera fil 60 Item no. 06845
Impeller for sera fil 120 Item no. 06847
Suction cup set for sera fil 60 Item no. 06846
Suction cup set including brace for sera fil 120 Item no.
06848

SAFETY PRECAUTIONS:

1. The sera fil 60/120 aquarium filter must only be op-

erated fully submerged! Operation outside the
water, even only for a short while, can damage the
filter. This is not covered by warranty.

2. The sera fil 60/120 must only be used for the indicat-

ed purpose. Operation is only permitted with special
sera filter media (see item list). Using other filter
media may damage the pump head or the shaft. This
is not covered by warranty. Operation without filter
media and/or filter chambers is not permitted.

3. Damage of the pump head, the cable or the plug

must not be repaired! In this case the filter must im-
mediately be disconnected from mains supply, and
must not be operated any more. This is also applies
in case of intended alterations of these parts. This
kind of damage must not be repaired or mended!

4. The temperature of the liquid to be pumped must

not exceed 35°C (95°F).

Not saltwater proof!

Advice for optimal function:

Biological aquarium filters such as the sera fil 60/120
must be operated without interruptions. They may
only be switched off for a short while (max. 30 minutes)
for maintenance purposes. The filter media must only
be rinsed coarsely. Biological filters must never be
‘disinfected’. It is important that you always preserve a
sufficient amount of purification bacteria for re-sett-
ling. We recommend applying sera filter biostart and
sera nitrivec biostarter every time the aquarium filter
was switched off. Check the nitrite level of the aquar-
ium water twice weekly for at least 4 weeks running by
means of the sera nitrite-Test (NO

2

), every time you 

rinsed (cleaned) the filter media. Frequently clogged

filters indicate that the number of fish is too high!
Normal fish stock provided, maintenance is required
every 3 – 4 months, 6 – 12 months with optimal fish
stock. Regularly check the intake grid of the filter
chamber, and remove attached plant parts.

Technical Data:

sera fil 60 (item no. 06843)
230 V ~ 50 Hz, 7 Watts, 380 l/h (100 US gal./h), H 0.9 m
(3 ft.) delivery height, for aquariums up to 60 l (16 US
gal.).
sera fil 120 (item no. 06844)
230 V ~ 50 Hz, 10 Watts, 700 l/h (185 US gal.), H 1.35 m 
(4.4 ft.) delivery height, for aquariums up to 120 l 
(32 US gal.).

Disposal of the unit:
Waste electrical and electronic equipment (WEEE)
must not get into domestic waste!
If ever the unit cannot be used anymore, the consumer
is legally obliged to hand in waste electrical and elec-
tronic equipment (WEEE) separately from domestic
waste
, e.g. at a collection point of his community/his
district. This ensures that waste electrical and elec-
tronic equipment (WEEE) is expertly processed and
that negative effects to the environment are avoided.

Therefore electrical and electronic 
equipment bears the following symbol: 

Warranty:

When following the directions for use the sera fil 60/
120  
internal aquarium filter will perform reliably. We
are liable for the freedom from faults of our products
only within legal regulations beginning with the pur-
chase date.
We  are liable for complete flawlessness at delivery.
Should usual wear and tear occur by use as intended
by us, this is not considered a defect. Warranty claims
are also excluded in this case.
In every case of a defect we recommend that you con-
sult the specialized retailer where you purchased the
unit. He will be able to judge whether it is actually a
warranty case. In case of sending the unit to us we will
unnecessarily have to charge you for occurring costs.
Any liability because of contract breach is limited to
intent or gross negligence. sera will be liable in case of
slight negligence only in case of injuries to life, body
and health, in case of essential contractual obligations
and with binding liability according to the product lia-
bility code. In that case, the extent of liability is limited
to the replacement of contractually typically foreseea-
ble damages.

Summary of Contents for Precision fil 120

Page 1: ...12 111111111111111111111131 37 09INT fil 60 120 Aquarium Innenfilter Internal Aquarium Filter Filtre int rieur pour aquarium D US F...

Page 2: ...e sch ma 60 18 17 19 19 16 15 15 14 13 12 11 10 9 6 5 4 3 2 1 18 17 16 12 15 15 14 9 3 1 Technische nderungen und Irrtum vorbehalten Subject to technical alterations and errors Sous r serve de modific...

Page 3: ...a 120 3 18 17 16 12 18 17 19 19 16 15 15 14 13 12 11 10 8 6 7 4 3 6 5 4 3 2 1 15 15 14 8 3 3 1 Technische nderungen und Irrtum vorbehalten Subject to technical alterations and errors Sous r serve de m...

Page 4: ...r sera fil 120 Connectur cartouche pour SERA fil 120 9 Kartuschenverbinder f r sera fil 60 Cartridge connector for sera fil 60 Connectur cartouche pour SERA fil 60 10 Rotordeckel mit Dichtungsring Imp...

Page 5: ...nternal Aquarium Filter 7 F Filtres int rieurs pour aquarium fil 60 120 10 NL fil 60 120 Aquariumbinnenfilters 12 I Filtri interni per acquari fil 60 120 14 E Filtros interiores para acuarios fil 60 1...

Page 6: ...hlrohr 17 mit den Saugern 19 und den dazugeh rigen Klips unter der Wasser oberfl che so dass die Austrittsd sen des Strahlrohres leicht nach oben in Richtung der Wasseroberfl che zeigen So erzeugen Si...

Page 7: ...erhalten bleiben Wir empfehlen die Anwendung von sera filter biostart und sera nitrivec Biostarter nach jedem Still stand des Aquarienfilters Testen Sie nach jedem Sp len Reinigen der Filtermedien f...

Page 8: ...sur face in a way that the outlet nozzles of the spray bar are slightly directed upwards to the water surface This will create a desired surface current which is very important for the oxygen supply o...

Page 9: ...ns of the sera nitrite Test NO2 every time you rinsed cleaned the filter media Frequently clogged filters indicate that the number of fish is too high Normal fish stock provided maintenance is require...

Page 10: ...fixer Puis fixez le tube diffuseur 17 avec les ventouses 19 et les clips correspondants sous la surface de l eau de mani re ce que les buses de sortie du tube diffuseur soient l g rement dirig es vers...

Page 11: ...iostart et SERA nitrivec apr s chaque arr t du filtre de l aqua rium Apr s chaque rin age nettoyage des m dias de filtration testez la teneur en nitrites de l eau de l aqua rium avec le test nitrites...

Page 12: ...der het wateropper vlak dat de spuitopeningen van de straalbuis enigszins naar boven in de richting van het wateroppervlak gericht zijn Zo zorgt u voor de gewenste oppervlakte stroming die erg belangr...

Page 13: ...pnieuw kunnen ontwikkelen Wij raden aan om na iedere stilstand van het aquariumfil ter de sera filter biostart en sera nitrivec te gebruiken Test na elke spoeling reiniging van het filtermateriaal ged...

Page 14: ...ione della superficie dell acqua In questo modo create un movimento in superficie che molto impor tante per rifornire d ossigeno i vostri pesci Negli schemi sono illustrati i singoli componenti di cui...

Page 15: ...lla settimana il valore dei nitriti nell acqua dell acquario con il SERA nitrit Test NO2 Filtri che si intasano frequentemente stanno ad indicare un numero di pesci troppo alto Con un numero di pesci...

Page 16: ...clips correspondientes debajo de la superficie del agua de forma que las boquillas de sali da del tubo perforado apunten ligeramente hacia arri ba en direcci n a la superficie del agua As generar la...

Page 17: ...or semana con el SERA test de nitrito NO2 Los filtros que se obturan con frecuencia indican una poblaci n demasiado grande de peces Con una poblaci n de peces normal normalmente se debe realizar el ma...

Page 18: ...os do tubo perfurado apontem ligei ramente para cima em direc o superf cie da gua Assim cria a corrente desejada na superf cie que muito importante para o fornecimento de oxig nio dos seus peixes Nas...

Page 19: ...o valor de nitrito da gua do aqu rio com o SERA teste de nitritos NO2 2 vezes por semana durante pelo menos 4 semanas Os filtros frequente mente entupidos s o um ind cio que a quantidade de peixes dem...

Reviews: