Solenoid diaphragm pump
Series R/RS 204.1
Operating Instructions
TA 416
Rev.
11 en
04/2013
Subject to technical modifications!
www.sera-web.com
35
3 sec.
START
STOP
START
STOP
AUTO
MANU
+
3 sec.
START
STOP
AUTO
MANU
+
10.7.4 Switching off the venting
To deactivate the previously set venting mode, use the keys as
described in the following diagram:
Go to the venting set-
ting mode
Keep pressing the
STOP/START key un-
til
all 3 LEDs flash
quickly
Exit the venting setting
mode
11
Maintenance
CAUTION !
Before starting maintenance work make sure the the spare
and wearing parts as well as the utilities required are
available.
Place / deposit components in such a way that any dam-
age is prevented.
CAUTION !
Check the wearing parts for proper functioning at regular
intervals and replace, if necessary.
The following checks should be carried out at regular intervals:
tight fit of the the pipework
tight fit of pressure and suction valve
proper condition of the electrical connections
tight fit of the screws for fastening the pump body (check
this at least every three months)
For the tightening torques of the fixing screws, please see
Chapter 8.1 “Installation”.
Repairs on the stroke mechanism may only be performed by
sera
.
11.1 Wearing parts
Depending on their use and period of use, wearing parts must
be replaced at regular intervals in order to ensure a safe func-
tion of the solenoid diaphragm pump.
We recommend to replace the drive diaphragm after 3000 op-
erating hours or at least once a year.
In case of a premature diaphragm rupture caused by hard op-
erating conditions, switch off the solenoid diaphragm pump
and replace the drive diaphragm (see Chapter 10.4).
As an option, the solenoid diaphragm pump can be equipped
with a diaphragm rupture monitoring device MBE-
… (please
see Chapter 7.2.7).
The following parts are considered as wearing parts of the so-
lenoid diaphragm pump:
Drive diaphragm
Suction valve
Suction valve
11.2 Spare parts
The following parts are considered as spare parts of the sole-
noid diaphragm pump:
Pump body
Vent valve (only with FRP-design, R 204.1-
1,2e…-14e,
RS 204.1-
6,0e …-14e)
Automatic ventilation device (RS 204.1)