INSTALLATION OF THE END STOP SLIDING PLATES

 

 

A - POSITIONING 

 

 

 

ATTENTION!

 

For safety reasons 
install the

leaf 

mechanic end 
stops for both 
opening

and 

closing 
movements. 

•  Move manually the leaf along the rail up to 5cm from the closing position. 
•  Position the closing sliding plate over the tooth rack starting from the opening side of the leaf, and make it slide towards the 

closing position until it operates the closing limit switch through the actuator spring: you'll hear a "click". 

•  Repeat for the opening position with the other sliding plate. 

 

ATTENTION! 
• To guarantee a correct limit switch operation, ensure a distance of 30mm (tolerance ±5mm) 

between the rear side of the operator and the sliding plates. A distance greater than 35mm can 
cause the leaf to block when reaching opening or closing positions. A distance smaller than 
25mm can cause the actuator spring breakage. 

• The sliding plates should be set taking into account inertia and temperature variations, so that 

the leaf should never reach the mechanic end stops during opening and closing movements. 
Otherwise THE RELEASE FLAP COULD GET BROKEN while attempting to release the operator 
mechanism. Because of seasonal temperature differences, it is advised to control the actual leaf 
stop positions both is summer and in winter. 

B - FASTENING 

 

 

 

• Once found the correct position, fasten the closing sliding 

plate to the tooth rack using 2 supplied M6 grub screws. 

•  Repeat for the opening sliding plate. 

 

 

• If necessary, the sliding plate can be shortened cutting a 

piece and then bending part of the remaining plate. 

 

DEFINITIVE OPERATOR FASTENING

 

 

 

• Tighten the nuts on the J-

bolts completely. 

•  Put the plastic band back in 

place and then the operator 
plastic cover. Fix it at the 
sides with its 2 screws. 

 

• 

Lock the operator by 
manually closing the release 
flap and taking off the
release key from the lock. 

•  Move manually the leaf for a few centimetres in any direction until the pinion locks. 

 

IN CASE OF POWER SUPPLY LOSS: MANUAL RELEASE OF THE OPERATOR 

 

•  Fit the release key into the lock in the front panel of the operator unit and give it half turn anti-

clockwise. 

•  Push the release flap strongly downwards until the release mechanism is triggered. 
•  The leaf can now manually be moved freely. 

 

 

 

ATTENTION!

 

The leaf should not stop against the mechanical end stops, otherwise the 
release flap could break when applying the force necessary to move it. 

 

•  To relock the operator, close the release flap and taking off the release key from the lock. 
•  Move manually the leaf for a few centimetres in any direction until the pinion locks. 

 

Summary of Contents for MT/604

Page 1: ...es RoHS 2011 65 UE Generic reference standards Household and similar electrical appliances safety part 1 generic standards EN60335 1 2013 Electromagnetic compatibility immunity part 2 generic standard...

Page 2: ...IRONMENTS 1 Verify the presence of an isolating switch upstream the installation with an open contact clearance of 3mm or higher 2 Before operating any wiring switch OFF the isolating switch the 0 sym...

Page 3: ...SE PLATE A Screw one nut onto each of the 2 J bolt until it is positioned 35mm from the end Fit the J bolts through the holes in the base plate Screw another nut onto each J bolt without tightening B...

Page 4: ...ating the grub screws Fit the washers onto the J bolts then screw the 2 nuts without tightening them completely These nuts will have to be tightened only after the definitive placement of the tooth ra...

Page 5: ...plates width is covered Fix the bars using self tapping M6 screws not supplied Upon completion of the installation vertically adjust the rack position through its slots so that moving manually the lea...

Page 6: ...e differences it is advised to control the actual leaf stop positions both is summer and in winter B FASTENING Once found the correct position fasten the closing sliding plate to the tooth rack using...

Page 7: ...7 MT 404 MT 604 MT 804 CABLES DESCRIPTION CONNECTING OPERATOR AND OTHER DEVICES TO THE STANDARD CR 62 CONTROL UNIT...

Page 8: ...a power loss When the power returns the leaf can be at half path Next command will cause a decelerated realignment to an end limit switch Next manoeuvres will be regular The leaf moves slowly even ou...