background image

Page 3/6

M

T

/B

4

-C

4

 I

 E

BRACKET POSITIONING FOR INWARD OPENING

BRACKET POSITIONING FOR OUTWARD OPENING

C

PM

INWARD OPENING

OUTWARD OPENING

PM

B

C

735 mm

B

Fig. 5

Fig. 4

ELECTRICAL CONNECTION
SET-UP

6- Before installing the motor, open the rear section af-

ter releasing by means of the safety key supplied – 
Fig. 6 - 

7- Loosen the internal screw by means of a Phillips 

screwdriver

-Fig. 7 -. Raise the top casing by tilting it by a couple of 

degrees, then pull out horizontally. - Fig. 8 -

8- Remove the lower casing by loosening the 3 lower 

screws.

- Fig. 8 -

9- The rear wall of the lower casing has a blank-out sec-

tion for cable routing.   Fix the cable using a cable 
clamp PG11 - Fig. 9 - 

Use an outdoor cable that remains flexible
at low temperatures.

   OPENING ANGLE  90°

OPENING ANGLE 100°

OPENING ANGLE  110°

B

  C

C

C

180

105

170

115

160

95

160

118

150

105

130

120

150

130

140

120

120

130

140

140

130

130

110

140

130

150

120

135

110

150

120

160

110

145

110

167

100

155

100

176

90

165

90

185

 

Warning: to ensure correct gate movement, use values in the shaded band

.

 The gate opening (or closing) time varies according to the selected values B and C.

Fig. 6

Fig. 7

Fig. 8

!

WARNING:
if inclined 
excessively, the 
connector tooth 
may break.

Fig. 9

1

2

!

PUNCH-OUT WALLS

SIN

CE

 1

96

5

Reviews: