Page 3/6
M
T
/B
4
-C
4
I
E
BRACKET POSITIONING FOR INWARD OPENING
BRACKET POSITIONING FOR OUTWARD OPENING
C
PM
INWARD OPENING
OUTWARD OPENING
PM
B
C
735 mm
B
Fig. 5
Fig. 4
ELECTRICAL CONNECTION
SET-UP
6- Before installing the motor, open the rear section af-
ter releasing by means of the safety key supplied –
Fig. 6 -
7- Loosen the internal screw by means of a Phillips
screwdriver
-Fig. 7 -. Raise the top casing by tilting it by a couple of
degrees, then pull out horizontally. - Fig. 8 -
8- Remove the lower casing by loosening the 3 lower
screws.
- Fig. 8 -
9- The rear wall of the lower casing has a blank-out sec-
tion for cable routing. Fix the cable using a cable
clamp PG11 - Fig. 9 -
Use an outdoor cable that remains flexible
at low temperatures.
OPENING ANGLE 90°
OPENING ANGLE 100°
OPENING ANGLE 110°
B
C
B
C
B
C
180
105
170
115
160
95
160
118
150
105
130
120
150
130
140
120
120
130
140
140
130
130
110
140
130
150
120
135
110
150
120
160
110
145
110
167
100
155
100
176
90
165
90
185
Warning: to ensure correct gate movement, use values in the shaded band
.
The gate opening (or closing) time varies according to the selected values B and C.
Fig. 6
Fig. 7
Fig. 8
!
WARNING:
if inclined
excessively, the
connector tooth
may break.
Fig. 9
1
2
!
PUNCH-OUT WALLS
SIN
CE
1
96
5