Device Specifications
Physical Characteristics
W x D x H: 30mm x 62mm x 16mm (1.18” x
2.44” x 0.63”)
Weight: 28.35g (1oz)
Power Source
Internal rechargeable Lithium-Polymer
battery 3.7VDC, 150mAH
Expected Battery Life: 1000 scans
Charges via standard USB port
Operating Temperature:
10 - 40
°
C (14 - 104
°
F)
Ambient Light Rejection
Fluorescent: 4,000 lx max
Direct Sunlight: 80,000 lx max
Incandescent: 4,000 lx max
Warranty:
One year
Maximum Barcode Digits:
At least 70 digits
Laser:
JIS-C-6802 Class 2, IEC 60825-1 Class 2, FDA
CDRH Class II
Operating System Support
Android tablets that support USB
keyboards
Linux – USB keyboard
Mac OS X – USB keyboard
Windows7/2008/Vista/XP/2003/2000 –
USB keyboard, SerialMagic, and Scan List
Magic
Bar Code Symbologies Decoded
All standard 1D symbologies:
JAN/UPC/EAN incl. add on, Codabar/NW-
7, Code 11, Code 39, Code 93, Code 128,
GS1-128 (EAN-128), GS1 DataBar (RSS),
IATA, Industrial 2of5, Interleaved 2of5,
ISBN-ISSN, Matrix 2of5, MSI/Plessey, S-
Code, Telepen, Tri-Optic, UK/Plessey
Control Codes for Batch Mode
Enable batch mode (save
scans to scanner memory):
ÉÁ]DTME+P!ËÍ
Store Scans
Save scans and timestamp to
scanner memory:
ÉÁ]DTME+Q)ËÍ
Store Scans and Timestamp
Send scans from scanner
memory:
ÉÁ+-MDLD-+!ËÍ
Send Scans
Erase scans from scanner
memory:
ÉÁ+-MCLR-+~ËÍ
Erase Scans
Send scan followed by a new
line:
ÉÁRYRZ1MGËÍ
CR after Scan
Disable batch mode (do not
save scans to memory):
ÉÁ]DTMDQËÍ
Real-Time Only
Control Codes for Keyboard Mode
Send data only (no prefix, no
suffix):
ÉÁMGPR9ËÍ
Data Only
Send barcode value then CR
(Use for Safari iOS):
ÉÁRZ7QMG/ËÍ
Data then CR
Send barcode value then
ENTER (use for Safari OS X):
ÉÁRZ1MMGjËÍ
Data then Enter
Send barcode value then
TAB:
ÉÁRZ7HMGiËÍ
Data then Tab
Send barcode value then
COMMA:
ÉÁRZ5MMGzËÍ
Data then Comma
Send barcode value for Grid-
In-Hand® Mobile Grid:
ÉÁRY1BRZ7HMGYËÍ
Mobile Grid KB