SUP-1200D can instantly switches your computer to emergency battery backup power and
allows you to work through brief power outages without data loss or downtime. It continuo
usly conditions the power coming into your computer and providing power supply for virtually
zero interruption. This state-of-the-art UPS is specially designed for PC users and also suitable
for computer peripherals or POS. Besides its space-saving compact size, this UPS also impress
you with its elegant appearance. The attractive LCD display enables you to check the UPS
working status at any time. A microprocessor is used as the controller that renders the product
an intelligent UPS capable of self-protection and fault diagnosis. Build-in AVR function autom
atically adjusts itself to maintain a power supply of stable voltage when the utility power is of
extra high or low voltage. High-performance surge suppression protects your computer from
electrical noise and damaging power surges.
.
Uninterruptible Power
Protects your data by supplying battery backup when power fails.
Microprocessor Control
By means of innovative software control programs, the complicated hardware circuitry is inlaid
in the powerful microprocessor. Apart from reduced size, it also lowers the defective rate of UPS.
LCD Display and Audible Alarms
Actively let you know if the unit is on battery, if the battery is low, or if there is an overload condition.
High quality battery
The selection of high quality sealed lead-acid maintenance free battery maximizes the life span of the
battery for enhanced economic benefits.
Automatic Detection
When the UPS is powered on, it immediately performs an inspection of the battery capacity.
Automatic Voltage Regulation
Corrects over- and under-voltages, without draining the battery. This preserves battery resources and
ensures your UPS will provide the optimum runtime during a complete blackout.
Surge Protection
Shields hardware from damage
Automatic Charge
The UPS charges its battery whenever it is connected to utility power.
Protection for Tel/Fax/Modem Connection
Protect the Tel/Fax/Modem from lightning and spike disturb.
Inspection
Inspect the UPS upon receipt. The packaging is recyclable. Save it for reuse or dispose of it properly.
Placement
Install the UPS in a protected area with adequate airflow, and away from direct sunlight and excessive
dust. Do not operate the UPS where the temperature and humidity is outside the specified limits in
the Specifications Table.
Connect to Utility
Connect the AC input power connector to utility power to power up the UPS.
Charge the battery
The battery in the UPS will lose some charge in shipping and storage. It will recharge completely
after approximately 8 hours of normal operation. Do not except full battery run time during this initial
recharge period.
Connect the loads
Plug the loads into the output connectors on the rear of the UPS.
Caution:
Never connect a laser printer or plotter to the UPS with other computer equipment. A laser
printer or plotter periodically draws significantly more power than when idle, and may overload the UPS.
Normal: Utility power in normal condition.
Fault: Utility power unusual or other problem occur.
Overload: UPS overload. The buzzer emits continuous alarm for 30 seconds.
Charge: Battery charge mode.
Battery: UPS transfer to backup or battery test mode. The buzzer emits alarm every four seconds.
Load: Capacity indicator
Battery: Capacity indicator
Power switch: Power on-off /*Battery test and buzzer on-off
Output socket: Connect with load equipment
Input socket: Connect with utility power
Fuse set: Built-in fuse avoid damaged by short circuit or overload.
Communication interface port: Connect to the computer with the communication cable. (Optional)
Input phone jack: Insert the phone line into the jack. (optional)
Output phone jack: Connect to the Tel / Fax / Modem by another phone line. (optional)
2
3
4
5
6
7
8
9
10
11
12
13
14
9
10
11
12
13
14
Switch On
With the UPS plugged in, press and hold the POWER button more than 4 seconds until hearing one
beep sound to switch the UPS on. The UPS will perform self-testing each time when it is switched on.
Switch Off
By pressing and hold the POWER button more than 4 seconds until hearing one beep sound.
Self-Test
In normal utility power, push the POWER button less than 1 second and UPS performs a self-test
on the battery capacity. During the self-test, the UPS operates a back up mode, the BATTERY and
FAULT icon stay on.
Silence
In Back-up mode, push the POWER button less than 1 second to silence the audible alarm.
Back Up (slow alarm)
When in Back Up mode, the BATTERY and FAULT icon illuminates and the UPS emit beeping
sound every four seconds. The alarms stops when the UPS return to the utility power operation.
Press the POWER button to stop the beeping.
Low Battery (rapid alarm)
In Back Up mode, when the battery energy runs low, the UPS beeps rapidly until the UPS shuts
down from battery exhaustion or return to utility power operation.
Overload (continuous alarm)
When the UPS is overloaded, the OVERLOAD icon illuminates and the UPS emits continuous
alarm for 30 seconds to warn an overload condition. Disconnect nonessential load equipment
from UPS to eliminate the overload.