SUP-1200D  can  instantly  switches  your  computer  to  emergency  battery  backup  power  and 
allows  you  to  work  through  brief  power  outages  without  data  loss  or  downtime.  It  continuo
usly conditions the power coming into your computer and providing power supply for virtually 
zero interruption. This state-of-the-art UPS is specially designed for PC users and also suitable 
for computer peripherals or POS. Besides its space-saving compact size, this UPS also impress 
you  with  its  elegant  appearance.  The  attractive  LCD  display  enables  you  to  check  the  UPS 
working status at any time. A microprocessor is used as the controller that renders the product 
an intelligent UPS capable of self-protection and fault diagnosis. Build-in AVR function autom
atically adjusts itself to maintain a power supply of stable voltage when the utility power is of 
extra  high  or  low  voltage.  High-performance  surge  suppression  protects  your  computer  from 
electrical noise and damaging power surges.                                                                                  

 .

Uninterruptible Power

  

Protects your data by supplying battery backup when power fails.  

Microprocessor Control

  

By means of innovative software control programs, the complicated hardware circuitry is inlaid 
in the powerful microprocessor. Apart from reduced size, it also lowers the defective rate of UPS.

LCD Display and Audible Alarms

  

Actively let you know if the unit is on battery, if the battery is low, or if there is an overload condition.  

High quality battery

 

The selection of high quality sealed lead-acid maintenance free battery maximizes the life span of the 
battery for enhanced economic benefits.

Automatic Detection

When the UPS is powered on, it immediately performs an inspection of the battery capacity.

Automatic Voltage Regulation

  

Corrects over- and under-voltages, without draining the battery. This preserves battery resources and 
ensures your UPS will provide the optimum runtime during a complete blackout.

Surge Protection

  

Shields hardware from damage  

Automatic Charge

  

The UPS charges its battery whenever it is connected to utility power.

Protection for Tel/Fax/Modem Connection

Protect the Tel/Fax/Modem from lightning and spike disturb.

Inspection

  

Inspect the UPS upon receipt. The packaging is recyclable. Save it for reuse or dispose of it properly. 

Placement  

Install the UPS in a protected area with adequate airflow, and away from direct sunlight and excessive 
dust. Do not operate the UPS where the temperature and humidity is outside the specified limits in 
the Specifications Table. 

Connect to Utility  

Connect the AC input power connector to utility power to power up the UPS.

Charge the battery

The battery in the UPS will lose some charge in shipping and storage. It will recharge completely 
after approximately 8 hours of normal operation. Do not except full battery run time during this initial 
recharge period.

Connect the loads

Plug the loads into the output connectors on the rear of the UPS. 

Caution:

 Never connect a laser printer or plotter to the UPS with other computer equipment. A laser 

printer or plotter periodically draws significantly more power than when idle, and may overload the UPS.

Normal: Utility power in normal condition.
Fault: Utility power unusual or other problem occur.  
Overload: UPS overload. The buzzer emits continuous alarm for 30 seconds.
Charge: Battery charge mode.
Battery: UPS transfer to backup or battery test mode. The buzzer emits alarm every four seconds.
Load: Capacity indicator
Battery: Capacity indicator
Power switch: Power on-off /*Battery test and buzzer on-off
Output socket: Connect with load equipment
Input socket: Connect with utility power
Fuse set: Built-in fuse avoid damaged by short circuit or overload.
Communication interface port: Connect to the computer with the communication cable. (Optional)
Input phone jack: Insert the phone line into the jack. (optional)
Output phone jack: Connect to the Tel / Fax / Modem by another phone line. (optional)

2

3

4

5

6

7

8

9

10

11

12

13

14

9

10

11

12

13

14

Switch On

With the UPS plugged in, press and hold the POWER button more than 4 seconds until hearing one 
beep sound to switch the UPS on. The UPS will perform self-testing each time when it is switched on.

Switch Off

By pressing and hold the POWER button more than 4 seconds until hearing one beep sound.

Self-Test

In normal utility power, push the POWER button less than 1 second and UPS performs a self-test 
on the battery capacity. During the self-test, the UPS operates a back up mode, the BATTERY and 
FAULT icon stay on.  

Silence

In Back-up mode, push the POWER button less than 1 second to silence the audible alarm.

Back Up (slow alarm)

When in Back Up mode, the BATTERY and FAULT icon illuminates and the UPS emit beeping 
sound every four seconds. The alarms stops when the UPS return to the utility power operation. 
Press the POWER button to stop the beeping.

Low Battery (rapid alarm)

In Back Up mode, when the battery energy runs low, the UPS beeps rapidly until the UPS shuts 
down from battery exhaustion or return to utility power operation.

Overload (continuous alarm)

When the UPS is overloaded, the OVERLOAD icon illuminates and the UPS emits continuous 
alarm for 30 seconds to warn an overload condition. Disconnect nonessential load equipment 
from UPS to eliminate the overload.