background image

PUMP CLEANING 

BEFORE FIRST USE AND AFTER USE DAILY, 

DISASSEMBLE AND CLEAN PUMP. 

STAINLESS STEEL PARTS CAN CORRODE. 

IT IS IMPORTANT TO CLEAN, RINSE, SANITIZE, AND 

DRY THESE PARTS DAILY AND PROPERLY. 

FAILURE TO COMPLY WITH ANY OF THESE 

INSTRUCTIONS MAY VOID UNIT WARRANTY.

SEE PUMP DISASSEMBLY.

WASH AND SCRUB ALL PARTS WITH 

DISHWASHING DETERGENT AND HOT WATER 

DAILY. 

• 

Wash small parts in a pan or other 

container to prevent part loss.

• 

Use supplied brushes to clean all confined 

areas. Maintain a clean and efficient pump 

by using the brushes supplied with pump 

to prevent product build up inside pump.

• 

IMPORTANT PUMP AREAS TO CLEAN:  

Clean inside cylinder thoroughly with 

brush 82049. Clean inside discharge tube 

and valve body thoroughly with brush 

82526/82824.

• 

Do not use abrasive cleansers, scrapers, steel 

pads, steel wool, or other cleaning tools that can 

scratch surfaces.

• 

A general purpose, nonabrasive cleaner may be 

used on hard to remove food deposits.

• 

Do not use cleansing agents with high 

concentrations of acid, alkaline or chlorine.  

These agents can corrode stainless steel.

• 

Do not use ammonia to clean pump parts.  

Ammonia can damage plastic parts.

• 

A nontoxic glass cleaner may be used for 

cleaning any stainless steel parts.

FULLY RINSE ALL PARTS THOROUGHLY WITH 

CLEAR WATER. 

• 

Fully rinsing all parts can help prevent corrosion.

DRY ALL STAINLESS STEEL PARTS WITH A CLEAN 

SOFT CLOTH. 

• 

Various elements and minerals, such as chlorides 

in tap water, can accumulate on stainless steel 

parts and create corrosion. 

• 

To prevent corrosion on any stainless steel parts, 

it is important to fully dry with a clean soft cloth 

regularly.

SANITIZE PARTS FOLLOWING YOUR LOCAL 

SANITIZATION REQUIREMENTS.  

ALL PARTS IN CONTACT WITH FOOD MUST BE 

SANITIZED.

• 

Allow parts to fully air dry after sanitization.

• 

Dishwasher safe.

CLEAN-IN-PLACE PROCEDURE 

FOR PUMPS 

CLEAN-IN-PLACE IS A BASIC FOUR STEP PUMP 

FLUSHING PROCESS: CLEAN, RINSE, SANITIZE, AND 

RINSE. 

CLEAN:

PUMP OUT ALL (IF ANY) REMAINING FOOD 

PRODUCT FROM INSIDE PUMP.

WASH AND RINSE OFF OUTSIDE OF PUMP.

FLUSH OUT AND RINSE THROUGH INSIDE OF 

PUMP.

• 

Place lower end of pump into container full 

of water and operate pump until all (if any) 

remaining product is expelled and only warm 

water flows from discharge tube. 

MIX 2 OZ (5 ML) OF DISHWASHING DETERGENT 

(DAWN DISHWASHING LIQUID) WITH 1 QUART  

(.95 L) OF HOT TAP WATER (APPROXIMATELY 

110°F/43°C).

PLACE LOWER END OF PUMP INTO THIS 

CLEANING MIXTURE AND REPEATEDLY OPERATE 

PUMP UNTIL ALL CLEANING MIXTURE IS PUMPED 

THROUGH PUMP.

RINSE:

PLACE LOWER END OF PUMP INTO 2 CUPS (.5 L) 

OF HOT TAP WATER (APPROXIMATELY 110°F/43°C) 

AND REPEATEDLY OPERATE PUMP UNTIL ALL TAP 

WATER IS PUMPED THROUGH PUMP.

SANITIZE:

MIX ONE 1 OZ (30 ML) PACKET OF KAY-5  

SANITIZER/CLEANER (EPA REG NO. 5389-15) 

WITH  

2.5 GALLONS (9.5 L) OF TAP WATER 

(APPROXIMATELY ROOM TEMPERATURE).

PLACE LOWER END OF PUMP INTO THIS 

SANITIZING MIXTURE AND REPEATEDLY OPERATE 

PUMP UNTIL 1 QUART (.95 L) SANITIZING 

MIXTURE IS PUMPED THROUGH PUMP.

RINSE:

PLACE LOWER END OF PUMP INTO 1 CUP (.24 L) 

OF HOT TAP WATER (APPROXIMATELY 110°F/43°C) 

AND REPEATEDLY OPERATE PUMP UNTIL ALL TAP 

WATER IS PUMPED THROUGH PUMP.

Summary of Contents for CSP

Page 1: ...eries 12G 94144 PUMP CSP 1 OZ Series 12G 94040 EZ CREAM 5 16 OUNCE 120V Series 13E 94160 PUMP CSP 5 16 OZ EZ CREAM Series 13E 94150 CSP CHILLED SERVER WITH PUMP 2 OUNCE 120V Series 12G 94050 230V Continental Europe Series 12G 94145 230V Australia Series 12G 94146 230V United Kingdom Series 12G 94147 PUMP CSP 2 OZ Series 12G 94140 01672 RevE_102813_ENGLISH ...

Page 2: ...d by sauerkraut or Aus Jus Do not place plastic lid plastic cover plastic top or plastic chiller block insulation assembly under in or near to high heat as this can melt the plastic UNIT SET UP ALWAYS CLEAN UNIT THOROUGHLY BEFORE EACH USE SEE UNIT TAKE DOWN SAFETY GUIDELINES AND UNIT CLEANING SEE SEPARATE PUMP MANUAL FOR PUMP INSTRUCTIONS 1 PLUG CORD INTO POWER SOURCE Verify that cord is securely ...

Page 3: ... dishwashing detergent Fully rinse 6 IF NECESSARY WIPE DOWN FAN COVER AND SURROUNDING AREA ON UNDERSIDE OF UNIT WITH CLOTH DAMPENED WITH DISHWASHING LIQUID OR MILD SANITIZING DETERGENT C EWarning Electrical shock could occur Be sure to wring out any excess water from cloth before wiping near fan of unit Dripping water into unit can cause electrical damage to unit 7 PLACE NEW OR CLEANED FILTER OVER...

Page 4: ...RING FROM DISCHARGE TUBE Be careful not to damage o ring when prying it off of discharge tube 8 REMOVE KNOB FROM PLUNGER ASSEMBLY BY ROTATING COUNTERCLOCKWISE Firmly hold head tube towards piston head while unscrewing knob Pressure on spring will release and push knob off rapidly 9 REMOVE LOCKING COLLAR FROM HEAD TUBE Remove gaging collar s if used from head tube by sliding them off J REMOVE HEAD ...

Page 5: ...e on stainless steel parts and create corrosion To prevent corrosion on any stainless steel parts it is important to fully dry with a clean soft cloth regularly 5 SANITIZE PARTS FOLLOWING YOUR LOCAL SANITIZATION REQUIREMENTS ALL PARTS IN CONTACT WITH FOOD MUST BE SANITIZED Allow parts to fully air dry after sanitization Dishwasher safe CLEAN IN PLACE PROCEDURE FOR PUMPS CLEAN IN PLACE IS A BASIC F...

Page 6: ...LOCKWISE TO SECURE TO THREADS OF DISCHARGE TUBE Do not use any sharp tools for assembly this can damage parts b a c VALVE COVER ASSEMBLY PUMP TROUBLESHOOTING PROBLEMS WITH PUMP OPERATION AND OR FLOW Clean pump PUMP DISPENSES LITTLE OR NO PRODUCT Product may be too stiff or contain a solid that will not pass through pump PORTION CONTROL IS NOT CONSISTENT Inspect gaging collar for any damage and or ...

Page 7: ...D END OF PISTON Firmly hold head tube towards piston head compressing spring while screwing knob on INSTALL O RINGS AND ASSEMBLE PUMP BODY 9 INSTALL SMALL O RING ONTO DISCHARGE TUBE Apply food equipment lubricant on o ring Be careful not to damage o ring while installing and or rolling onto discharge tube J INSTALL SILICONE GASKET OR O RING INTO VALVE BODY Apply food equipment lubricant on silicon...

Page 8: ...TH ANY OF THESE INSTRUCTIONS MAY VOID UNIT WARRANTY 1 SEE UNIT TAKE DOWN PUMP DISASSEMBLY AND PUMP CLEANING 2 ENSURE UNIT IS OFF AND UNPLUGGED C EWarning Electrical shock could occur Electrical components of unit could be damaged from water exposure or any liquid Never immerse unit into water or any liquid Never use any water jet or pressure sprayer on unit 3 WASH PRODUCT VESSEL AND PUMP WITH DISH...

Reviews: